Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 1996 |
Principal Product | 2'x4'studs |
NAICS | n/a |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 44,000 |
Annual Production | 81,000,000 Thousand Feet |
Production Hrs. Annual | 4,500 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $785,102 | 11,031,946 | kWh | $0.07 |
Electricity Demand | $183,369 | 26,528 | kW-months/year | $6.91 |
Electricity Fees | $302 | - | $ | - |
LPG | $6,477 | 2,997 | MMBtu | $2.16 |
Fuel Oil #2 | $27,853 | 7,000 | MMBtu | $3.98 |
TOTAL ENERGY COSTS | $1,003,103 | |||
RECOMMENDED SAVINGS* | $82,208 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $64,208 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Fuel Oil #2 | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $23,160 Cost: $1,200 |
$23,160 | 330,891 | - | - | - | - | - | - | - | - |
$23,160 330,891 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $18,000 Cost: $26,280 |
- | - | - | - | - | - | - | - | $18,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$18,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $8,553 Cost: $10,500 |
$8,553 | 122,216 | - | - | - | - | - | - | - | - |
$8,553 122,216 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $8,809 Cost: - |
$8,809 | 125,733 | - | - | - | - | - | - | - | - |
$8,809 125,733 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,901 Cost: $13,040 |
$4,893 | 70,047 | $1,008 | 146 | - | - | - | - | - | - |
$4,893 70,047 kWh |
$1,008 146 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4325 UPGRADE CONVEYORS |
Savings: $5,339 Cost: $6,100 |
$4,641 | 66,237 | $698 | 199 | - | - | - | - | - | - |
$4,641 66,237 kWh |
$698 199 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $5,206 Cost: $6,000 |
$3,732 | 53,341 | $2,379 | 344 | $(-905) | (-227) | - | - | - | - |
$3,732 53,341 kWh |
$2,379 344 kW-months/year |
$(-905) (-227) MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $3,000 Cost: $9,500 |
- | - | - | - | - | - | $3,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$3,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $3,133 Cost: - |
$3,133 | 44,842 | - | - | - | - | - | - | - | - |
$3,133 44,842 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $1,107 Cost: - |
- | - | - | - | - | - | $1,107 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,107 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $82,208 Cost: $72,620 |
$56,921 | 813,307 | $4,085 | 689 | $(-905) | (-227) | $4,107 | - | $18,000 | - | $56,921 813,307 kWh |
$4,085 689 kW-months/year |
$(-905) (-227) MMBtu |
$4,107 - $ |
$18,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $64,208 Cost: $46,340 |
$56,921 | 813,307 | $4,085 | 689 | $(-905) | (-227) | $4,107 | - | - | - | $56,921 813,307 kWh |
$4,085 689 kW-months/year |
$(-905) (-227) MMBtu |
$4,107 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Fuel Oil #2 | Administrative Changes | Ancillary Material Cost |