Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 1999 |
Principal Product | Packaging |
NAICS | n/a |
SIC | 3082 - Unsupported Plastics Profile Shapes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 240 |
Plant Area (Sq.Ft.) | 55,000 |
Annual Production | 15,120,000 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $492,245 | 7,575,323 | kWh | $0.06 |
Electricity Demand | $111,600 | 17,885 | kW-months/year | $6.24 |
LPG | $46,007 | 8,009 | MMBtu | $5.74 |
TOTAL ENERGY COSTS | $649,852 | |||
RECOMMENDED SAVINGS* | $88,086 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,836 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | LPG | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2711 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING |
Savings: $19,520 Cost: $4,860 |
$19,520 | 300,410 | - | - | - | - | - | - |
$19,520 300,410 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $11,434 Cost: $2,159 |
- | - | - | - | $11,434 | 1,654 | - | - |
- - kWh |
- - kW-months/year |
$11,434 1,654 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,056 Cost: $22,438 |
$10,461 | 160,903 | $1,595 | 256 | - | - | - | - |
$10,461 160,903 kWh |
$1,595 256 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $9,306 Cost: $450 |
$9,306 | 143,318 | - | - | - | - | - | - |
$9,306 143,318 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $9,306 Cost: $500 |
$9,306 | 143,318 | - | - | - | - | - | - |
$9,306 143,318 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $9,227 Cost: $850 |
$9,227 | 142,732 | - | - | - | - | - | - |
$9,227 142,732 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $5,265 Cost: - |
- | - | - | - | - | - | $5,265 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,265 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $5,172 Cost: $5,760 |
$4,964 | 76,202 | $2,021 | 324 | $(-1,813) | (-325) | - | - |
$4,964 76,202 kWh |
$2,021 324 kW-months/year |
$(-1,813) (-325) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,760 Cost: $7,122 |
$2,438 | 37,515 | $322 | 52 | - | - | - | - |
$2,438 37,515 kWh |
$322 52 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $2,141 Cost: $7,579 |
$1,909 | 26,377 | $823 | 132 | $(-591) | (-106) | - | - |
$1,909 26,377 kWh |
$823 132 kW-months/year |
$(-591) (-106) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,899 Cost: $1,260 |
- | - | - | - | $1,899 | 100 | - | - |
- - kWh |
- - kW-months/year |
$1,899 100 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $88,086 Cost: $52,978 |
$67,131 | 1,030,775 | $4,761 | 764 | $10,929 | 1,323 | $5,265 | - | $67,131 1,030,775 kWh |
$4,761 764 kW-months/year |
$10,929 1,323 MMBtu |
$5,265 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,836 Cost: $16,751 |
$16,708 | 257,035 | $2,343 | 376 | $11,520 | 1,429 | $5,265 | - | $16,708 257,035 kWh |
$2,343 376 kW-months/year |
$11,520 1,429 MMBtu |
$5,265 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | LPG | One-time Revenue or Avoided Cost |