Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 2000 |
Principal Product | Athletic Shoes |
NAICS | n/a |
SIC | 3144 - Women's Footwear, Except Athletic |
Sales | $10,000,000-$50,000,000 |
# of Employees | 375 |
Plant Area (Sq.Ft.) | 127,785 |
Annual Production | 1,600,000 Pieces |
Production Hrs. Annual | 2,500 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $130,872 | 2,181,712 | kWh | $0.06 |
Electricity Demand | $94,755 | 7,455 | kW-months/year | $12.71 |
Fuel Oil #2 | $18,592 | 5,880 | MMBtu | $3.16 |
TOTAL ENERGY COSTS | $247,969 | |||
RECOMMENDED SAVINGS* | $100,517 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $65,298 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Fuel Oil #2 | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Fuel Oil #2 | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $46,375 Cost: - |
- | - | - | - | - | - | - | - | - | - | $46,375 | 775,000 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
$46,375 775,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $30,810 Cost: - |
- | - | - | - | $30,810 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$30,810 - $ |
- - MMBtu |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $7,566 Cost: $16,265 |
$9,431 | 160,023 | - | - | - | - | - | - | $(-1,865) | (-579) | - | - | - | - |
$9,431 160,023 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$(-1,865) (-579) MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $1,006 Cost: $1,750 |
$3,216 | 54,513 | - | - | - | - | $(-2,210) | (-233) | - | - | - | - | - | - |
$3,216 54,513 kWh |
- - kW-months/year |
- - $ |
$(-2,210) (-233) MMBtu |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $3,750 Cost: $850 |
- | - | - | - | - | - | - | - | - | - | - | - | $3,750 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - lb |
$3,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,736 Cost: $80 |
$3,736 | 62,427 | - | - | - | - | - | - | - | - | - | - | - | - |
$3,736 62,427 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,865 Cost: $3,563 |
$1,569 | 26,084 | $1,296 | 102 | - | - | - | - | - | - | - | - | - | - |
$1,569 26,084 kWh |
$1,296 102 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,558 Cost: $1,844 |
- | - | - | - | - | - | - | - | $2,558 | 556 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$2,558 556 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $1,851 Cost: $2,515 |
$1,851 | 31,360 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,851 31,360 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $100,517 Cost: $26,867 |
$19,803 | 334,407 | $1,296 | 102 | $30,810 | - | $(-2,210) | (-233) | $693 | (-23) | $46,375 | 775,000 | $3,750 | - | $19,803 334,407 kWh |
$1,296 102 kW-months/year |
$30,810 - $ |
$(-2,210) (-233) MMBtu |
$693 (-23) MMBtu |
$46,375 775,000 lb |
$3,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $65,298 Cost: $22,508 |
$17,952 | 303,047 | $1,296 | 102 | - | - | $(-2,210) | (-233) | $(-1,865) | (-579) | $46,375 | 775,000 | $3,750 | - | $17,952 303,047 kWh |
$1,296 102 kW-months/year |
- - $ |
$(-2,210) (-233) MMBtu |
$(-1,865) (-579) MMBtu |
$46,375 775,000 lb |
$3,750 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | LPG | Fuel Oil #2 | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | LPG | Fuel Oil #2 | Solid Waste (non-haz) | Personnel Changes |