IAC logo
IAC Assessment: MI0046
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0046
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2002
Principal Product Sand and gravel quarry
NAICS n/a
SIC 1442 - Construction Sand And Gravel
Sales $10,000,000-$50,000,000
# of Employees 25
Plant Area (Sq.Ft.) 0
Annual Production 2,000,000 Tons
Production Hrs. Annual 2,730
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $184,929 3,238,237 kWh $0.06
Electricity Demand $83,777 29,529 kW-months/year $2.84
TOTAL ENERGY COSTS $268,706
RECOMMENDED SAVINGS* $134,958 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $60,708
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Primary Product Electricity Usage Electricity Demand Primary Product
$ kWh $ kW-months/year $ $
01: 4.6110 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$74,250
Cost:
$5,460
- - - - $74,250 - -
-
kWh
-
-
kW-months/year
$74,250
-
$
02: 4.6510 INSTALL BACK-UP EQUIPMENT Savings:
$27,428
Cost:
$936
- - - - $27,428 - -
-
kWh
-
-
kW-months/year
$27,428
-
$
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$16,162
Cost:
$1,016
- - $16,162 481 - - -
-
kWh
$16,162
481
kW-months/year
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$9,120
Cost:
$1,068
$8,178 136,309 $942 28 - - $8,178
136,309
kWh
$942
28
kW-months/year
-
-
$
05: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS Savings:
$7,998
Cost:
$8
- - - - $7,998 - -
-
kWh
-
-
kW-months/year
$7,998
-
$
TOTAL RECOMMENDED Savings:
$134,958
Cost:
$8,488
$8,178 136,309 $17,104 509 $109,676 - $8,178
136,309
kWh
$17,104
509
kW-months/year
$109,676
-
$
TOTAL IMPLEMENTED Savings:
$60,708
Cost:
$3,028
$8,178 136,309 $17,104 509 $35,426 - $8,178
136,309
kWh
$17,104
509
kW-months/year
$35,426
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Primary Product Electricity Usage Electricity Demand Primary Product