Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2011 |
Principal Product | Fruit Juice |
NAICS | 311421 - Fruit and Vegetable Canning |
SIC | 2033 - Canned Fruits And Vegetables |
Sales | $10,000,000-$50,000,000 |
# of Employees | 500 |
Plant Area (Sq.Ft.) | 360,220 |
Annual Production | 25,000 Thousand Gallons |
Production Hrs. Annual | 4,284 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,741,806 | 37,391,841 | kWh | $0.07 |
Electricity Demand | $498,673 | 71,239 | kW-months/year | $7.00 |
Electricity Fees | $20,197 | - | $ | - |
Fuel Oil #2 | $3,486,258 | 160,673 | MMBtu | $21.70 |
Fuel Oil #6 | $3,197,676 | 217,981 | MMBtu | $14.67 |
TOTAL ENERGY COSTS | $9,944,609 | |||
RECOMMENDED SAVINGS* | $5,220,446 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,746,720 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Fuel Oil #6 | Administrative Changes | Electricity Usage | Electricity Demand | Fuel Oil #2 | Fuel Oil #6 | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $4,297,734 Cost: $3,000,000 |
- | - | - | - | $367,716 | 16,947 | $323,077 | 22,023 | $3,606,941 | - |
- - kWh |
- - kW-months/year |
$367,716 16,947 MMBtu |
$323,077 22,023 MMBtu |
$3,606,941 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2447 HEAT WATER WITH EXHAUST HEAT |
Savings: $240,185 Cost: $30,000 |
- | - | - | - | $240,185 | 8,164 | - | - | - | - |
- - kWh |
- - kW-months/year |
$240,185 8,164 MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $192,436 Cost: $36,000 |
- | - | - | - | $192,436 | 6,541 | - | - | - | - |
- - kWh |
- - kW-months/year |
$192,436 6,541 MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4159 REPLACE TREATED WATER WITH WELL / SURFACE WATER |
Savings: $132,137 Cost: $500,000 |
$61,907 | 884,389 | $20,230 | 2,890 | - | - | - | - | $50,000 | - |
$61,907 884,389 kWh |
$20,230 2,890 kW-months/year |
- - MMBtu |
- - MMBtu |
$50,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $112,996 Cost: $1,950 |
- | - | - | - | $112,996 | 3,841 | - | - | - | - |
- - kWh |
- - kW-months/year |
$112,996 3,841 MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $107,940 Cost: $330,568 |
$87,395 | 1,197,175 | $20,545 | 2,940 | - | - | - | - | - | - |
$87,395 1,197,175 kWh |
$20,545 2,940 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $32,204 Cost: $29,679 |
$28,249 | 403,553 | $3,955 | 565 | - | - | - | - | - | - |
$28,249 403,553 kWh |
$3,955 565 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $27,599 Cost: $1,320 |
$24,611 | 337,132 | $2,988 | 427 | - | - | - | - | - | - |
$24,611 337,132 kWh |
$2,988 427 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $13,681 Cost: $50 |
$11,892 | 162,907 | $1,789 | 256 | - | - | - | - | - | - |
$11,892 162,907 kWh |
$1,789 256 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $22,382 Cost: $2,550 |
$19,631 | 280,439 | $2,751 | 393 | - | - | - | - | - | - |
$19,631 280,439 kWh |
$2,751 393 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $10,779 Cost: $45,345 |
$5,736 | 81,943 | $5,043 | 720 | - | - | - | - | - | - |
$5,736 81,943 kWh |
$5,043 720 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $13,268 Cost: $3,200 |
- | - | - | - | $13,268 | 451 | - | - | - | - |
- - kWh |
- - kW-months/year |
$13,268 451 MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $7,944 Cost: $2,000 |
$6,971 | 99,590 | $973 | 139 | - | - | - | - | - | - |
$6,971 99,590 kWh |
$973 139 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $5,235 Cost: $3,450 |
$5,235 | 74,784 | - | - | - | - | - | - | - | - |
$5,235 74,784 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $3,926 Cost: $3,450 |
$3,926 | 56,088 | - | - | - | - | - | - | - | - |
$3,926 56,088 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $5,220,446 Cost: $3,989,562 |
$255,553 | 3,578,000 | $58,274 | 8,330 | $926,601 | 35,944 | $323,077 | 22,023 | $3,656,941 | - | $255,553 3,578,000 kWh |
$58,274 8,330 kW-months/year |
$926,601 35,944 MMBtu |
$323,077 22,023 MMBtu |
$3,656,941 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,746,720 Cost: $3,873,667 |
$223,215 | 3,116,028 | $49,507 | 7,078 | $493,980 | 21,239 | $323,077 | 22,023 | $3,656,941 | - | $223,215 3,116,028 kWh |
$49,507 7,078 kW-months/year |
$493,980 21,239 MMBtu |
$323,077 22,023 MMBtu |
$3,656,941 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Fuel Oil #6 | Administrative Changes | Electricity Usage | Electricity Demand | Fuel Oil #2 | Fuel Oil #6 | Administrative Changes |