Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2012 |
Principal Product | Fruit Juice Concentrates |
NAICS | 311411 - Frozen Fruit, Juice, and Vegetable Manufacturing |
SIC | 2037 - Frozen Fruits And Vegetables |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 467,000 |
Annual Production | 4,500,000 Pieces |
Production Hrs. Annual | 8,736 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,209,860 | 18,060,000 | kWh | $0.07 |
Electricity Demand | $215,491 | 33,360 | kW-months/year | $6.46 |
Electricity Fees | $88,271 | - | $ | - |
TOTAL ENERGY COSTS | $1,513,621 | |||
RECOMMENDED SAVINGS* | $226,335 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $176,461 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $114,097 Cost: $23,031 |
$100,751 | 1,503,744 | $13,346 | 2,066 | - | - |
$100,751 1,503,744 kWh |
$13,346 2,066 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $29,492 Cost: $29,008 |
$26,256 | 364,663 | $3,236 | 501 | - | - |
$26,256 364,663 kWh |
$3,236 501 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $27,049 Cost: $190,339 |
$13,453 | 200,791 | $13,596 | 2,105 | - | - |
$13,453 200,791 kWh |
$13,596 2,105 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $19,052 Cost: $1,660 |
$15,880 | 237,015 | $3,172 | 491 | - | - |
$15,880 237,015 kWh |
$3,172 491 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $13,619 Cost: $520 |
$12,026 | 179,504 | $1,593 | 247 | - | - |
$12,026 179,504 kWh |
$1,593 247 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $11,955 Cost: $800 |
- | - | - | - | $11,955 | - |
- - kWh |
- - kW-months/year |
$11,955 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2447 HEAT WATER WITH EXHAUST HEAT |
Savings: $5,925 Cost: $8,000 |
$3,495 | 52,162 | $2,430 | 376 | - | - |
$3,495 52,162 kWh |
$2,430 376 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $2,502 Cost: $2,372 |
$2,211 | 32,996 | $291 | 45 | - | - |
$2,211 32,996 kWh |
$291 45 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,598 Cost: $80 |
$1,311 | 19,563 | $287 | 41 | - | - |
$1,311 19,563 kWh |
$287 41 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,046 Cost: $255 |
$923 | 13,771 | $123 | 19 | - | - |
$923 13,771 kWh |
$123 19 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $226,335 Cost: $256,065 |
$176,306 | 2,604,209 | $38,074 | 5,891 | $11,955 | - | $176,306 2,604,209 kWh |
$38,074 5,891 kW-months/year |
$11,955 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $176,461 Cost: $215,885 |
$144,344 | 2,154,388 | $32,117 | 4,969 | - | - | $144,344 2,154,388 kWh |
$32,117 4,969 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes |