Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2013 |
Principal Product | Asphalt |
NAICS | 324121 - Asphalt Paving Mixture and Block Manufacturing |
SIC | 2951 - Asphalt Paving Mixtures And Blocks |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 500,000 |
Annual Production | 200,000 Tons |
Production Hrs. Annual | 2,964 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $48,365 | 912,720 | kWh | $0.05 |
Electricity Demand | $46,994 | 4,693 | kW-months/year | $10.01 |
Electricity Fees | $15,352 | - | $ | - |
Natural Gas | $670,266 | 170,724 | MMBtu | $3.93 |
Fuel Oil #2 | $3,600,000 | 126,895 | MMBtu | $28.37 |
TOTAL ENERGY COSTS | $4,380,978 | |||
RECOMMENDED SAVINGS* | $1,921,158 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,874,270 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $1,845,922 Cost: $2,000,000 |
- | - | - | - | - | - | $1,845,922 | 65,066 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,845,922 65,066 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $38,483 Cost: $20,790 |
- | - | - | - | $38,483 | 9,718 | - | - |
- - kWh |
- - kW-months/year |
$38,483 9,718 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8226 INCREASE EFFICIENCY OF TRUCKS |
Savings: $14,224 Cost: $11,600 |
- | - | - | - | - | - | $14,224 | 501 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$14,224 501 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,076 Cost: $13,090 |
$5,283 | 99,674 | $2,793 | 278 | - | - | - | - |
$5,283 99,674 kWh |
$2,793 278 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $5,223 Cost: $2,520 |
- | - | - | - | $5,223 | 1,319 | - | - |
- - kWh |
- - kW-months/year |
$5,223 1,319 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT |
Savings: $2,451 Cost: $347 |
$1,387 | 26,167 | $1,064 | 106 | - | - | - | - |
$1,387 26,167 kWh |
$1,064 106 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,546 Cost: $1,660 |
$1,167 | 22,024 | $2,379 | 237 | - | - | - | - |
$1,167 22,024 kWh |
$2,379 237 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,904 Cost: $80 |
$1,756 | 33,140 | $1,148 | 114 | - | - | - | - |
$1,756 33,140 kWh |
$1,148 114 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $329 Cost: $1,104 |
- | - | - | - | $329 | 83 | - | - |
- - kWh |
- - kW-months/year |
$329 83 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,921,158 Cost: $2,051,191 |
$9,593 | 181,005 | $7,384 | 735 | $44,035 | 11,120 | $1,860,146 | 65,567 | $9,593 181,005 kWh |
$7,384 735 kW-months/year |
$44,035 11,120 MMBtu |
$1,860,146 65,567 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,874,270 Cost: $2,016,207 |
$4,310 | 81,331 | $4,591 | 457 | $5,223 | 1,319 | $1,860,146 | 65,567 | $4,310 81,331 kWh |
$4,591 457 kW-months/year |
$5,223 1,319 MMBtu |
$1,860,146 65,567 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 |