Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | University of Miami |
---|---|
Assessment Year | 2014 |
Principal Product | Flower Bouquets |
NAICS | 453110 - Florists |
SIC | 5992 - Florists |
Sales | $100,000,000-$500,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 450,000,000 Pieces |
Production Hrs. Annual | 8,736 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $158,572 | 3,427,920 | kWh | $0.05 |
Electricity Demand | $73,036 | 5,913 | kW-months/year | $12.35 |
Electricity Fees | $52,138 | - | $ | - |
TOTAL ENERGY COSTS | $402,893 | |||
RECOMMENDED SAVINGS* | $219,658 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $134,262 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $27,195 Cost: $1,120 |
- | - | - | - | - | - | $27,195 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$27,195 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $28,983 Cost: $9,620 |
$21,203 | 458,374 | $7,780 | 630 | - | - | - | - | - | - |
$21,203 458,374 kWh |
$7,780 630 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $24,961 Cost: $480 |
- | - | - | - | - | - | - | - | $24,961 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$24,961 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $24,870 Cost: $12,900 |
$18,201 | 393,453 | $6,669 | 540 | - | - | - | - | - | - |
$18,201 393,453 kWh |
$6,669 540 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $24,844 Cost: $820 |
$18,175 | 392,894 | $6,669 | 540 | - | - | - | - | - | - |
$18,175 392,894 kWh |
$6,669 540 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $20,044 Cost: $640 |
- | - | - | - | - | - | $20,044 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$20,044 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE |
Savings: $16,496 Cost: $160 |
$12,049 | 261,928 | $4,447 | 360 | - | - | - | - | - | - |
$12,049 261,928 kWh |
$4,447 360 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $11,171 Cost: $9,500 |
$8,207 | 177,422 | $2,964 | 240 | - | - | - | - | - | - |
$8,207 177,422 kWh |
$2,964 240 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4159 REPLACE TREATED WATER WITH WELL / SURFACE WATER |
Savings: $8,527 Cost: $17,000 |
- | - | - | - | $8,527 | 1,292 | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,527 1,292 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $6,636 Cost: $7,480 |
$4,858 | 105,015 | $1,778 | 144 | - | - | - | - | - | - |
$4,858 105,015 kWh |
$1,778 144 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $5,236 Cost: $320 |
$2,497 | 53,956 | $914 | 74 | - | - | $1,825 | - | - | - |
$2,497 53,956 kWh |
$914 74 kW-months/year |
- - Tgal |
$1,825 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $4,968 Cost: $3,309 |
$3,634 | 78,649 | $1,334 | 108 | - | - | - | - | - | - |
$3,634 78,649 kWh |
$1,334 108 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,304 Cost: $5,640 |
$2,415 | 52,203 | $889 | 72 | - | - | - | - | - | - |
$2,415 52,203 kWh |
$889 72 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,624 Cost: $2,320 |
$1,920 | 41,496 | $704 | 57 | - | - | - | - | - | - |
$1,920 41,496 kWh |
$704 57 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,303 Cost: $1,260 |
$1,685 | 36,435 | $618 | 50 | - | - | - | - | - | - |
$1,685 36,435 kWh |
$618 50 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,306 Cost: $10,640 |
$1,688 | 36,691 | $618 | 50 | - | - | - | - | - | - |
$1,688 36,691 kWh |
$618 50 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $1,975 Cost: $140 |
$1,444 | 31,215 | $531 | 43 | - | - | - | - | - | - |
$1,444 31,215 kWh |
$531 43 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
18: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,758 Cost: $80 |
$1,289 | 27,867 | $469 | 38 | - | - | - | - | - | - |
$1,289 27,867 kWh |
$469 38 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
19: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT |
Savings: $1,375 Cost: $347 |
$1,006 | 21,749 | $369 | 30 | - | - | - | - | - | - |
$1,006 21,749 kWh |
$369 30 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
20: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $82 Cost: $92 |
$60 | 1,299 | $22 | 2 | - | - | - | - | - | - |
$60 1,299 kWh |
$22 2 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $219,658 Cost: $83,868 |
$100,331 | 2,170,646 | $36,775 | 2,978 | $8,527 | 1,292 | $49,064 | - | $24,961 | - | $100,331 2,170,646 kWh |
$36,775 2,978 kW-months/year |
$8,527 1,292 Tgal |
$49,064 - $ |
$24,961 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $134,262 Cost: $43,096 |
$59,044 | 1,278,152 | $21,686 | 1,756 | $8,527 | 1,292 | $20,044 | - | $24,961 | - | $59,044 1,278,152 kWh |
$21,686 1,756 kW-months/year |
$8,527 1,292 Tgal |
$20,044 - $ |
$24,961 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Ancillary Material Cost |