Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2014 |
Principal Product | Flower Bouquets |
NAICS | 453110 - Florists |
SIC | 5992 - Florists |
Sales | $100,000,000-$500,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 450,000,000 Pieces |
Production Hrs. Annual | 8,736 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $158,572 | 3,427,920 | kWh | $0.05 |
Electricity Demand | $73,036 | 5,913 | kW-months/year | $12.35 |
Electricity Fees | $52,138 | - | $ | - |
TOTAL ENERGY COSTS | $402,893 | |||
RECOMMENDED SAVINGS* | $219,658 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $134,262 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $27,195 Cost: $1,120 |
- | - | - | - | - | - | $27,195 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$27,195 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $28,983 Cost: $9,620 |
$21,203 | 458,374 | $7,780 | 630 | - | - | - | - | - | - |
$21,203 458,374 kWh |
$7,780 630 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $24,961 Cost: $480 |
- | - | - | - | - | - | - | - | $24,961 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$24,961 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $24,870 Cost: $12,900 |
$18,201 | 393,453 | $6,669 | 540 | - | - | - | - | - | - |
$18,201 393,453 kWh |
$6,669 540 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $24,844 Cost: $820 |
$18,175 | 392,894 | $6,669 | 540 | - | - | - | - | - | - |
$18,175 392,894 kWh |
$6,669 540 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $20,044 Cost: $640 |
- | - | - | - | - | - | $20,044 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$20,044 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE |
Savings: $16,496 Cost: $160 |
$12,049 | 261,928 | $4,447 | 360 | - | - | - | - | - | - |
$12,049 261,928 kWh |
$4,447 360 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $11,171 Cost: $9,500 |
$8,207 | 177,422 | $2,964 | 240 | - | - | - | - | - | - |
$8,207 177,422 kWh |
$2,964 240 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4159 REPLACE TREATED WATER WITH WELL / SURFACE WATER |
Savings: $8,527 Cost: $17,000 |
- | - | - | - | $8,527 | 1,292 | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,527 1,292 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $6,636 Cost: $7,480 |
$4,858 | 105,015 | $1,778 | 144 | - | - | - | - | - | - |
$4,858 105,015 kWh |
$1,778 144 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $5,236 Cost: $320 |
$2,497 | 53,956 | $914 | 74 | - | - | $1,825 | - | - | - |
$2,497 53,956 kWh |
$914 74 kW-months/year |
- - Tgal |
$1,825 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $4,968 Cost: $3,309 |
$3,634 | 78,649 | $1,334 | 108 | - | - | - | - | - | - |
$3,634 78,649 kWh |
$1,334 108 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,304 Cost: $5,640 |
$2,415 | 52,203 | $889 | 72 | - | - | - | - | - | - |
$2,415 52,203 kWh |
$889 72 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,624 Cost: $2,320 |
$1,920 | 41,496 | $704 | 57 | - | - | - | - | - | - |
$1,920 41,496 kWh |
$704 57 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,303 Cost: $1,260 |
$1,685 | 36,435 | $618 | 50 | - | - | - | - | - | - |
$1,685 36,435 kWh |
$618 50 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,306 Cost: $10,640 |
$1,688 | 36,691 | $618 | 50 | - | - | - | - | - | - |
$1,688 36,691 kWh |
$618 50 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
17: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $1,975 Cost: $140 |
$1,444 | 31,215 | $531 | 43 | - | - | - | - | - | - |
$1,444 31,215 kWh |
$531 43 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
18: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,758 Cost: $80 |
$1,289 | 27,867 | $469 | 38 | - | - | - | - | - | - |
$1,289 27,867 kWh |
$469 38 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
19: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT |
Savings: $1,375 Cost: $347 |
$1,006 | 21,749 | $369 | 30 | - | - | - | - | - | - |
$1,006 21,749 kWh |
$369 30 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
20: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $82 Cost: $92 |
$60 | 1,299 | $22 | 2 | - | - | - | - | - | - |
$60 1,299 kWh |
$22 2 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $219,658 Cost: $83,868 |
$100,331 | 2,170,646 | $36,775 | 2,978 | $8,527 | 1,292 | $49,064 | - | $24,961 | - | $100,331 2,170,646 kWh |
$36,775 2,978 kW-months/year |
$8,527 1,292 Tgal |
$49,064 - $ |
$24,961 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $134,262 Cost: $43,096 |
$59,044 | 1,278,152 | $21,686 | 1,756 | $8,527 | 1,292 | $20,044 | - | $24,961 | - | $59,044 1,278,152 kWh |
$21,686 1,756 kW-months/year |
$8,527 1,292 Tgal |
$20,044 - $ |
$24,961 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Administrative Changes | Ancillary Material Cost |