Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2015 |
Principal Product | Muffins |
NAICS | 311812 - Commercial Bakeries |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 45 Tons |
Production Hrs. Annual | 8,736 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $133,685 | 2,609,520 | kWh | $0.05 |
Electricity Demand | $65,640 | 5,274 | kW-months/year | $12.45 |
Electricity Fees | $40,055 | - | $ | - |
Natural Gas | $61,054 | 15,062 | MMBtu | $4.05 |
TOTAL ENERGY COSTS | $332,333 | |||
RECOMMENDED SAVINGS* | $94,709 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $83,805 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $34,151 Cost: $1,660 |
$16,707 | 327,598 | $17,444 | 1,402 | - | - | - | - |
$16,707 327,598 kWh |
$17,444 1,402 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $14,336 Cost: $140 |
$14,336 | 281,099 | - | - | - | - | - | - |
$14,336 281,099 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $10,584 Cost: $14,880 |
- | - | - | - | - | - | $10,584 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$10,584 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $10,327 Cost: $4,691 |
$8,224 | 161,258 | $2,103 | 169 | - | - | - | - |
$8,224 161,258 kWh |
$2,103 169 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $8,833 Cost: $11,640 |
$6,633 | 130,052 | $2,200 | 180 | - | - | - | - |
$6,633 130,052 kWh |
$2,200 180 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,565 Cost: $40 |
$3,320 | 65,103 | $1,245 | 100 | - | - | - | - |
$3,320 65,103 kWh |
$1,245 100 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,430 Cost: $1,710 |
$3,430 | 67,251 | - | - | - | - | - | - |
$3,430 67,251 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,100 Cost: $639 |
$2,322 | 45,582 | $778 | 63 | - | - | - | - |
$2,322 45,582 kWh |
$778 63 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,582 Cost: $6,871 |
$1,935 | 37,942 | $647 | 52 | - | - | - | - |
$1,935 37,942 kWh |
$647 52 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $1,145 Cost: $780 |
- | - | - | - | - | - | $1,145 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,145 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $626 Cost: $360 |
- | - | - | - | $626 | 154 | - | - |
- - kWh |
- - kW-months/year |
$626 154 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $457 Cost: $160 |
$342 | 6,709 | $115 | 9 | - | - | - | - |
$342 6,709 kWh |
$115 9 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $320 Cost: $310 |
- | - | - | - | $320 | 79 | - | - |
- - kWh |
- - kW-months/year |
$320 79 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $253 Cost: $320 |
$253 | 4,964 | - | - | - | - | - | - |
$253 4,964 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $94,709 Cost: $44,201 |
$57,502 | 1,127,558 | $24,532 | 1,975 | $946 | 233 | $11,729 | - | $57,502 1,127,558 kWh |
$24,532 1,975 kW-months/year |
$946 233 MMBtu |
$11,729 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $83,805 Cost: $29,011 |
$57,502 | 1,127,558 | $24,532 | 1,975 | $626 | 154 | $1,145 | - | $57,502 1,127,558 kWh |
$24,532 1,975 kW-months/year |
$626 154 MMBtu |
$1,145 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |