Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2015 |
Principal Product | Printed Circuit Boards |
NAICS | 334418 - Printed Circuit Assembly (Electronic Assembly) Manufacturing |
SIC | 3672 - Printed Circuit Boards |
Sales | $50,000,000-$100,000,000 |
# of Employees | 462 |
Plant Area (Sq.Ft.) | 67,000 |
Annual Production | 300,000 Units |
Production Hrs. Annual | 7,488 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $493,327 | 7,462,700 | kWh | $0.07 |
Electricity Demand | $165,203 | 16,360 | kW-months/year | $10.10 |
Electricity Fees | $104,312 | - | $ | - |
TOTAL ENERGY COSTS | $762,842 | |||
RECOMMENDED SAVINGS* | $178,250 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $44,562 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $75,489 Cost: $140,000 |
$46,020 | 696,219 | $11,269 | 1,116 | $18,200 | - |
$46,020 696,219 kWh |
$11,269 1,116 kW-months/year |
$18,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE |
Savings: $54,079 Cost: $166,590 |
$43,446 | 657,270 | $10,633 | 1,053 | - | - |
$43,446 657,270 kWh |
$10,633 1,053 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $20,030 Cost: $160 |
$16,091 | 243,433 | $3,939 | 390 | - | - |
$16,091 243,433 kWh |
$3,939 390 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $18,361 Cost: $1,660 |
$13,502 | 204,260 | $4,859 | 481 | - | - |
$13,502 204,260 kWh |
$4,859 481 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,483 Cost: $9,820 |
$5,483 | 83,089 | - | - | - | - |
$5,483 83,089 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,494 Cost: $1,400 |
$1,999 | 30,287 | $495 | 49 | - | - |
$1,999 30,287 kWh |
$495 49 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $942 Cost: $40 |
$619 | 9,372 | $323 | 32 | - | - |
$619 9,372 kWh |
$323 32 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $688 Cost: $639 |
$553 | 8,369 | $135 | 13 | - | - |
$553 8,369 kWh |
$135 13 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $684 Cost: $177 |
$684 | 10,356 | - | - | - | - |
$684 10,356 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $178,250 Cost: $320,486 |
$128,397 | 1,942,655 | $31,653 | 3,134 | $18,200 | - | $128,397 1,942,655 kWh |
$31,653 3,134 kW-months/year |
$18,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $44,562 Cost: $12,279 |
$35,629 | 539,151 | $8,933 | 884 | - | - | $35,629 539,151 kWh |
$8,933 884 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |