Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2018 |
Principal Product | Pharmaceutical Pill Packaging |
NAICS | 339113 - Surgical Appliance and Supplies Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 320 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 840,000,000 Pieces |
Production Hrs. Annual | 6,120 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $387,392 | 5,993,700 | kWh | $0.06 |
Electricity Demand | $138,777 | 19,304 | kW-months/year | $7.19 |
Electricity Fees | $87,818 | - | $ | - |
TOTAL ENERGY COSTS | $613,987 | |||
RECOMMENDED SAVINGS* | $379,474 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $321,869 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $236,442 Cost: $800,000 |
$183,621 | 2,824,941 | $27,821 | 3,870 | $25,000 | - |
$183,621 2,824,941 kWh |
$27,821 3,870 kW-months/year |
$25,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE |
Savings: $37,140 Cost: $43,838 |
$32,251 | 496,164 | $4,889 | 680 | - | - |
$32,251 496,164 kWh |
$4,889 680 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $32,079 Cost: $2,030 |
$26,364 | 405,586 | $5,715 | 795 | - | - |
$26,364 405,586 kWh |
$5,715 795 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $30,500 Cost: $3,280 |
$30,500 | 469,227 | - | - | - | - |
$30,500 469,227 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $17,400 Cost: $71,328 |
$9,600 | 147,692 | $7,800 | 1,085 | - | - |
$9,600 147,692 kWh |
$7,800 1,085 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $16,044 Cost: $2,973 |
$13,183 | 202,819 | $2,861 | 398 | - | - |
$13,183 202,819 kWh |
$2,861 398 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $4,421 Cost: $1,005 |
$3,631 | 55,847 | $790 | 110 | - | - |
$3,631 55,847 kWh |
$790 110 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,552 Cost: $7,675 |
$2,732 | 42,032 | $820 | 114 | - | - |
$2,732 42,032 kWh |
$820 114 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,896 Cost: $6,486 |
$1,637 | 25,179 | $259 | 36 | - | - |
$1,637 25,179 kWh |
$259 36 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $379,474 Cost: $938,615 |
$303,519 | 4,669,487 | $50,955 | 7,088 | $25,000 | - | $303,519 4,669,487 kWh |
$50,955 7,088 kW-months/year |
$25,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $321,869 Cost: $890,799 |
$254,454 | 3,914,657 | $42,415 | 5,900 | $25,000 | - | $254,454 3,914,657 kWh |
$42,415 5,900 kW-months/year |
$25,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes |