IAC logo
IAC Assessment: MI0377
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0377
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2020
Principal Product pet bottles, jars
NAICS 326160 - Plastics Bottle Manufacturing
SIC 3085 - Plastics Bottles
Sales $10,000,000-$50,000,000
# of Employees 72
Plant Area (Sq.Ft.) 45,000
Annual Production 70,000,000 Pieces
Production Hrs. Annual 7,344
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $151,367 3,777,861 kWh $0.04
Electricity Demand $117,722 8,745 kW-months/year $13.46
Electricity Fees $37,460 - $ -
TOTAL ENERGY COSTS $324,492
RECOMMENDED SAVINGS* $34,220 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Disposal Electricity Usage Electricity Demand Water Disposal
$ kWh $ kW-months/year $ Tgal
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$9,975
Cost:
$1,980
$3,190 79,762 $6,785 504 - - $3,190
79,762
kWh
$6,785
504
kW-months/year
-
-
Tgal
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$7,215
Cost:
$2,100
$4,415 110,384 $2,800 208 - - $4,415
110,384
kWh
$2,800
208
kW-months/year
-
-
Tgal
03: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) Savings:
$4,058
Cost:
$1,306
- - - - $4,058 481 -
-
kWh
-
-
kW-months/year
$4,058
481
Tgal
04: 2.7252 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM Savings:
$3,560
Cost:
$17,760
$2,295 57,370 $1,265 94 - - $2,295
57,370
kWh
$1,265
94
kW-months/year
-
-
Tgal
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$2,125
Cost:
$2,048
$792 19,809 $1,333 99 - - $792
19,809
kWh
$1,333
99
kW-months/year
-
-
Tgal
06: 2.7229 AIR CONDITION ONLY SPACE NECESSARY Savings:
$1,976
Cost:
$4,415
$1,276 31,892 $700 52 - - $1,276
31,892
kWh
$700
52
kW-months/year
-
-
Tgal
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,479
Cost:
$1,875
$954 23,854 $525 39 - - $954
23,854
kWh
$525
39
kW-months/year
-
-
Tgal
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,242
Cost:
$1,042
$1,242 31,049 - - - - $1,242
31,049
kWh
-
-
kW-months/year
-
-
Tgal
09: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$1,158
Cost:
$1,827
- - $1,158 86 - - -
-
kWh
$1,158
86
kW-months/year
-
-
Tgal
10: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$744
Cost:
$965
$488 12,210 $256 19 - - $488
12,210
kWh
$256
19
kW-months/year
-
-
Tgal
11: 2.2511 INSULATE BARE EQUIPMENT Savings:
$688
Cost:
$682
$271 6,783 $417 31 - - $271
6,783
kWh
$417
31
kW-months/year
-
-
Tgal
TOTAL RECOMMENDED Savings:
$34,220
Cost:
$36,000
$14,923 373,113 $15,239 1,132 $4,058 481 $14,923
373,113
kWh
$15,239
1,132
kW-months/year
$4,058
481
Tgal
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ Tgal
Electricity Usage Electricity Demand Water Disposal Electricity Usage Electricity Demand Water Disposal