Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2022
Principal Product Diabetic Test strips
NAICS 339112 - Surgical and Medical Instrument Manufacturing
SIC 3841 - Surgical And Medical Instruments
Sales $100,000,000-$500,000,000
# of Employees 300
Plant Area (Sq.Ft.) 145,000
Annual Production 20,000,000 Pieces
Production Hrs. Annual 4,680
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $670,894 6,855,660 kWh $0.10
Electricity Demand $178,028 16,155 kW-months/year $11.02
Electricity Fees $92,946 - $ -
TOTAL ENERGY COSTS $941,868
RECOMMENDED SAVINGS* $114,592 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $81,911
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$51,243
Cost:
$208,000
$39,551 403,585 $11,692 1,061 $39,551
403,585
kWh
$11,692
1,061
kW-months/year
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$26,714
Cost:
$39,398
$20,741 211,644 $5,973 542 $20,741
211,644
kWh
$5,973
542
kW-months/year
03: 2.9112 USE SOLAR HEAT TO HEAT WATER Savings:
$22,766
Cost:
$62,612
$22,766 232,309 - - $22,766
232,309
kWh
-
-
kW-months/year
04: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$9,041
Cost:
$580
$7,829 79,885 $1,212 110 $7,829
79,885
kWh
$1,212
110
kW-months/year
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,954
Cost:
$3,600
$3,954 40,345 - - $3,954
40,345
kWh
-
-
kW-months/year
06: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$874
Cost:
$900
$753 7,681 $121 11 $753
7,681
kWh
$121
11
kW-months/year
TOTAL RECOMMENDED Savings:
$114,592
Cost:
$315,090
$95,594 975,449 $18,998 1,724 $95,594
975,449
kWh
$18,998
1,724
kW-months/year
TOTAL IMPLEMENTED Savings:
$81,911
Cost:
$250,998
$64,246 655,574 $17,665 1,603 $64,246
655,574
kWh
$17,665
1,603
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand