Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2025 |
Principal Product | Rum (Alcoholic Beverage)/Brandy spirits |
NAICS | 312140 - Distilleries |
SIC | 2085 - Distilled And Blended Liquors |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 2,831,400 |
Annual Production | 22,000 Thousand Gallons |
Production Hrs. Annual | 8,400 |
Location (State) | PR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $3,670,709 | 17,436,118 | kWh | $0.21 |
Electricity Demand | $288,835 | 28,755 | kW-months/year | $10.04 |
Electricity Fees | $(-9,591) | - | $ | - |
LPG | $8,000,000 | 529,452 | MMBtu | $15.11 |
TOTAL ENERGY COSTS | $11,949,953 | |||
RECOMMENDED SAVINGS* | $1,549,579 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Electricity Usage | Electricity Demand | LPG | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2111 INSTALL STEAM TRAP |
Savings: $1,094,206 Cost: $5,054 |
- | - | - | - | $1,094,206 | 72,416 |
- - kWh |
- - kW-months/year |
$1,094,206 72,416 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $328,069 Cost: $109,503 |
$328,069 | 1,594,224 | - | - | - | - |
$328,069 1,594,224 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $79,812 Cost: $90,256 |
- | - | $79,812 | 7,945 | - | - |
- - kWh |
$79,812 7,945 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $25,502 Cost: $240 |
$23,878 | 113,167 | $1,624 | 162 | - | - |
$23,878 113,167 kWh |
$1,624 162 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $13,314 Cost: $80 |
$12,241 | 58,013 | $1,073 | 107 | - | - |
$12,241 58,013 kWh |
$1,073 107 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $4,581 Cost: $40 |
$4,147 | 19,656 | $434 | 43 | - | - |
$4,147 19,656 kWh |
$434 43 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,479 Cost: $2,874 |
$2,062 | 9,774 | $417 | 41 | - | - |
$2,062 9,774 kWh |
$417 41 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,616 Cost: $3,453 |
$1,497 | 7,093 | $119 | 12 | - | - |
$1,497 7,093 kWh |
$119 12 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,549,579 Cost: $211,500 |
$371,894 | 1,801,927 | $83,479 | 8,310 | $1,094,206 | 72,416 | $371,894 1,801,927 kWh |
$83,479 8,310 kW-months/year |
$1,094,206 72,416 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Electricity Usage | Electricity Demand | LPG |