IAC logo
IAC Assessment: MO0066
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MO0066
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri, Rolla
Assessment Year 1992
Principal Product SPORTING GOODS
NAICS n/a
SIC 3949 - Sporting And Athletic Goods, Nec
Sales $10,000,000-$50,000,000
# of Employees 225
Plant Area (Sq.Ft.) 0
Annual Production 590,000 Pieces
Production Hrs. Annual 4,000
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $158,483 2,451,348 kWh $0.06
LPG $17,747 3,409 MMBtu $5.21
Fuel Oil #4 $17,113 5,751 MMBtu $2.98
TOTAL ENERGY COSTS $193,343
RECOMMENDED SAVINGS* $11,073 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,105
#|Description Savings
Cost
Status Electricity Usage Fuel Oil #4 Administrative Changes Electricity Usage Fuel Oil #4 Administrative Changes
$ kWh $ MMBtu $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,899
Cost:
$18,800
$1,899 29,308 - - - - $1,899
29,308
kWh
-
-
MMBtu
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,249
Cost:
$1,100
$2,488 38,687 - - $(-239) - $2,488
38,687
kWh
-
-
MMBtu
$(-239)
-
$
03: 3.4115 RECOVER AND REUSE COOLING WATER Savings:
$3,103
Cost:
$640
$127 2,052 - - $2,976 - $127
2,052
kWh
-
-
MMBtu
$2,976
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$224
Cost:
$250
$224 3,517 - - - - $224
3,517
kWh
-
-
MMBtu
-
-
$
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$439
Cost:
$4,000
$439 6,741 - - - - $439
6,741
kWh
-
-
MMBtu
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$311
Cost:
$210
$311 4,689 - - - - $311
4,689
kWh
-
-
MMBtu
-
-
$
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,207
Cost:
$1,200
- - $1,207 405 - - -
-
kWh
$1,207
405
MMBtu
-
-
$
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,433
Cost:
$973
$1,433 22,274 - - - - $1,433
22,274
kWh
-
-
MMBtu
-
-
$
09: 2.2511 INSULATE BARE EQUIPMENT Savings:
$208
Cost:
$69
$208 3,224 - - - - $208
3,224
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$11,073
Cost:
$27,242
$7,129 110,492 $1,207 405 $2,737 - $7,129
110,492
kWh
$1,207
405
MMBtu
$2,737
-
$
TOTAL IMPLEMENTED Savings:
$6,105
Cost:
$25,310
$5,137 79,425 $1,207 405 $(-239) - $5,137
79,425
kWh
$1,207
405
MMBtu
$(-239)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Fuel Oil #4 Administrative Changes Electricity Usage Fuel Oil #4 Administrative Changes