Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri, Rolla
Assessment Year 1992
Principal Product BRAKE DRUMS AND ROTORS
NAICS n/a
SIC 3321 - Gray And Ductile Iron Foundries
Sales $10,000,000-$50,000,000
# of Employees 390
Plant Area (Sq.Ft.) 0
Annual Production 17,000,000 Pieces
Production Hrs. Annual 6,240
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,840,020 39,230,950 kWh $0.05
Natural Gas $140,818 32,155 MMBtu $4.38
TOTAL ENERGY COSTS $1,980,838
RECOMMENDED SAVINGS* $131,781 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER Savings:
$64,793
Cost:
$300
- - $64,793 - - - -
-
kWh
$64,793
-
MMBtu
-
-
$
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$35,376
Cost:
$200
$35,376 754,103 - - - - $35,376
754,103
kWh
-
-
MMBtu
-
-
$
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$4,537
Cost:
$109,000
$4,537 96,717 - - - - $4,537
96,717
kWh
-
-
MMBtu
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$4,418
Cost:
$265
$4,418 94,080 - - - - $4,418
94,080
kWh
-
-
MMBtu
-
-
$
05: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$11,792
Cost:
-
$11,792 251,465 - - - - $11,792
251,465
kWh
-
-
MMBtu
-
-
$
06: 3.4115 RECOVER AND REUSE COOLING WATER Savings:
$8,112
Cost:
-
$205 4,396 - - $7,907 - $205
4,396
kWh
-
-
MMBtu
$7,907
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,709
Cost:
$18,500
$1,709 36,342 - - - - $1,709
36,342
kWh
-
-
MMBtu
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,044
Cost:
$1,000
$1,376 29,308 - - $(-332) - $1,376
29,308
kWh
-
-
MMBtu
$(-332)
-
$
TOTAL RECOMMENDED Savings:
$131,781
Cost:
$129,265
$59,413 1,266,411 $64,793 - $7,575 - $59,413
1,266,411
kWh
$64,793
-
MMBtu
$7,575
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes