Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri, Rolla
Assessment Year 1993
Principal Product Electric Motors
NAICS n/a
SIC 3621 - Motors And Generators
Sales $50,000,000-$100,000,000
# of Employees 502
Plant Area (Sq.Ft.) 96,000
Annual Production 1,300,000 Pieces
Production Hrs. Annual 5,880
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $333,687 8,022,274 kWh $0.04
LPG $7,551 1,396 MMBtu $5.41
TOTAL ENERGY COSTS $341,238
RECOMMENDED SAVINGS* $42,225 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $17,953
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,587
Cost:
$2,155
$5,587 134,232 $5,587
134,232
kWh
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,582
Cost:
$2,804
$2,582 62,134 $2,582
62,134
kWh
03: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$1,614
Cost:
$1,245
$1,614 38,687 $1,614
38,687
kWh
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,655
Cost:
$14,813
$5,655 135,991 $5,655
135,991
kWh
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,515
Cost:
$7,131
$2,515 60,375 $2,515
60,375
kWh
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$366
Cost:
$245
$366 8,792 $366
8,792
kWh
07: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$10,030
Cost:
$23,000
$10,030 241,208 $10,030
241,208
kWh
08: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$13,876
Cost:
$3,216
$13,876 (-187,280) $13,876
(-187,280)
kWh
TOTAL RECOMMENDED Savings:
$42,225
Cost:
$54,609
$42,225 494,139 $42,225
494,139
kWh
TOTAL IMPLEMENTED Savings:
$17,953
Cost:
$28,148
$17,953 431,419 $17,953
431,419
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage