Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri, Rolla
Assessment Year 1993
Principal Product Pharmaceuticals
NAICS n/a
SIC 2834 - Pharmaceutical Preparations
Sales $10,000,000-$50,000,000
# of Employees 135
Plant Area (Sq.Ft.) 90,000
Annual Production 970,779 Pounds
Production Hrs. Annual 4,200
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $431,140 10,041,911 kWh $0.04
Natural Gas $160,389 47,319 MMBtu $3.39
TOTAL ENERGY COSTS $591,529
RECOMMENDED SAVINGS* $45,793 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $39,492
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,128
Cost:
$734
$3,128 72,978 - - $3,128
72,978
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,250
Cost:
$18,608
$7,250 169,109 - - $7,250
169,109
kWh
-
-
MMBtu
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$4,833
Cost:
$1,440
$4,833 112,544 - - $4,833
112,544
kWh
-
-
MMBtu
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$17,959
Cost:
$28,210
$17,959 418,523 - - $17,959
418,523
kWh
-
-
MMBtu
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$4,375
Cost:
$225
$4,375 101,993 - - $4,375
101,993
kWh
-
-
MMBtu
06: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$1,468
Cost:
$2,008
$1,468 34,291 - - $1,468
34,291
kWh
-
-
MMBtu
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$1,153
Cost:
$1,595
- - $1,153 340 -
-
kWh
$1,153
340
MMBtu
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$5,627
Cost:
$1,200
$5,627 131,008 - - $5,627
131,008
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$45,793
Cost:
$54,020
$44,640 1,040,446 $1,153 340 $44,640
1,040,446
kWh
$1,153
340
MMBtu
TOTAL IMPLEMENTED Savings:
$39,492
Cost:
$50,572
$38,339 893,611 $1,153 340 $38,339
893,611
kWh
$1,153
340
MMBtu
Savings
Cost
$ kWh $ MMBtu