IAC logo
IAC Assessment: MO0110
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MO0110
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri, Rolla
Assessment Year 1994
Principal Product Battery Chargers
NAICS n/a
SIC 3629 - Electrical Industrial Apparatus, Nec
Sales $10,000,000-$50,000,000
# of Employees 190
Plant Area (Sq.Ft.) 230,900
Annual Production 320,420 Pieces
Production Hrs. Annual 4,160
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $88,558 1,143,318 kWh $0.08
Natural Gas $76,000 15,662 MMBtu $4.85
TOTAL ENERGY COSTS $164,558
RECOMMENDED SAVINGS* $31,967 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $12,118
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$13,598
Cost:
$32,200
- - $13,598 2,804 -
-
kWh
$13,598
2,804
MMBtu
02: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$140
Cost:
$80
$81 1,172 $59 12 $81
1,172
kWh
$59
12
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,941
Cost:
$22,684
$4,941 63,892 - - $4,941
63,892
kWh
-
-
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,377
Cost:
$1,232
$3,377 43,669 - - $3,377
43,669
kWh
-
-
MMBtu
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,882
Cost:
$4,863
$2,882 37,222 - - $2,882
37,222
kWh
-
-
MMBtu
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,789
Cost:
$350
$1,789 23,154 - - $1,789
23,154
kWh
-
-
MMBtu
07: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,519
Cost:
$2,083
$1,519 19,637 - - $1,519
19,637
kWh
-
-
MMBtu
08: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$1,310
Cost:
$1,806
$1,682 17,878 $(-372) (-263) $1,682
17,878
kWh
$(-372)
(-263)
MMBtu
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,424
Cost:
$40
$1,424 18,464 - - $1,424
18,464
kWh
-
-
MMBtu
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$987
Cost:
$1,093
$987 12,896 - - $987
12,896
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$31,967
Cost:
$66,431
$18,682 237,984 $13,285 2,553 $18,682
237,984
kWh
$13,285
2,553
MMBtu
TOTAL IMPLEMENTED Savings:
$12,118
Cost:
$9,741
$12,059 156,214 $59 12 $12,059
156,214
kWh
$59
12
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas