Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1996 |
Principal Product | Annual Reports, Point of Purchase Displays, Static Cling |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $10,000,000-$50,000,000 |
# of Employees | 77 |
Plant Area (Sq.Ft.) | 42,000 |
Annual Production | 2,000 Tons |
Production Hrs. Annual | 4,992 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $98,546 | 1,569,168 | kWh | $0.06 |
Electricity Demand | $8,763 | 4,670 | kW-months/year | $1.88 |
Natural Gas | $8,298 | 1,682 | MMBtu | $4.93 |
TOTAL ENERGY COSTS | $125,213 | |||
RECOMMENDED SAVINGS* | $13,479 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,597 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Gaseous Waste | Electricity Usage | Electricity Demand | Gaseous Waste | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,818 Cost: $8,136 |
$4,523 | 72,098 | $295 | 184 | - | - |
$4,523 72,098 kWh |
$295 184 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,614 Cost: $1,991 |
$2,456 | 38,980 | $158 | 98 | - | - |
$2,456 38,980 kWh |
$158 98 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $240 Cost: - |
$232 | 3,810 | $8 | 5 | - | - |
$232 3,810 kWh |
$8 5 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $253 Cost: $80 |
$228 | 3,517 | $25 | 16 | - | - |
$228 3,517 kWh |
$25 16 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $98 Cost: $125 |
$88 | 1,465 | $10 | 6 | - | - |
$88 1,465 kWh |
$10 6 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $441 Cost: $1,552 |
$416 | 6,741 | $25 | 16 | - | - |
$416 6,741 kWh |
$25 16 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $5,015 Cost: - |
- | - | - | - | $5,015 | 6,800 |
- - kWh |
- - kW-months/year |
$5,015 6,800 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $13,479 Cost: $11,884 |
$7,943 | 126,611 | $521 | 325 | $5,015 | 6,800 | $7,943 126,611 kWh |
$521 325 kW-months/year |
$5,015 6,800 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,597 Cost: $9,813 |
$5,259 | 84,114 | $338 | 211 | - | - | $5,259 84,114 kWh |
$338 211 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Gaseous Waste | Electricity Usage | Electricity Demand | Gaseous Waste |