Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri, Rolla
Assessment Year 1996
Principal Product Aluminum A/C Manifolds
NAICS n/a
SIC 3354 - Aluminum Extruded Products
Sales $10,000,000-$50,000,000
# of Employees 150
Plant Area (Sq.Ft.) 75,000
Annual Production 3,000,000 Pieces
Production Hrs. Annual 6,900
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $125,302 2,159,437 kWh $0.06
Electricity Demand $13,664 6,075 kW-months/year $2.25
Natural Gas $35,240 6,620 MMBtu $5.32
LPG $6,903 863 MMBtu $8.00
TOTAL ENERGY COSTS $201,109
RECOMMENDED SAVINGS* $26,201 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,398
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)
$ kWh $ kW-months/year $ lb
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$535
Cost:
$394
$500 8,499 $35 18 - - $500
8,499
kWh
$35
18
kW-months/year
-
-
lb
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$892
Cost:
$1,216
$830 14,361 $62 32 - - $830
14,361
kWh
$62
32
kW-months/year
-
-
lb
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,595
Cost:
$120
$1,512 26,084 $83 43 - - $1,512
26,084
kWh
$83
43
kW-months/year
-
-
lb
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$7,347
Cost:
$1,281
$6,962 119,871 $385 201 - - $6,962
119,871
kWh
$385
201
kW-months/year
-
-
lb
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$10,106
Cost:
$80
$9,558 164,713 $548 286 - - $9,558
164,713
kWh
$548
286
kW-months/year
-
-
lb
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$268
Cost:
-
$250 4,396 $18 10 - - $250
4,396
kWh
$18
10
kW-months/year
-
-
lb
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,458
Cost:
$3,003
$1,361 23,447 $97 50 - - $1,361
23,447
kWh
$97
50
kW-months/year
-
-
lb
08: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$4,000
Cost:
$8,000
- - - - $4,000 - -
-
kWh
-
-
kW-months/year
$4,000
-
lb
TOTAL RECOMMENDED Savings:
$26,201
Cost:
$14,094
$20,973 361,371 $1,228 640 $4,000 - $20,973
361,371
kWh
$1,228
640
kW-months/year
$4,000
-
lb
TOTAL IMPLEMENTED Savings:
$2,398
Cost:
$514
$2,262 38,979 $136 71 - - $2,262
38,979
kWh
$136
71
kW-months/year
-
-
lb
Savings
Cost
$ kWh $ kW-months/year $ lb
Electricity Usage Electricity Demand Solid Waste (non-haz) Electricity Usage Electricity Demand Solid Waste (non-haz)