Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1996 |
Principal Product | Rubber cushion |
NAICS | n/a |
SIC | 3069 - Fabricated Rubber Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 11,000,000 Units |
Production Hrs. Annual | 6,000 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $193,322 | 3,797,773 | kWh | $0.05 |
Electricity Demand | $24,712 | 11,426 | kW-months/year | $2.16 |
Natural Gas | $188,317 | 50,338 | MMBtu | $3.74 |
TOTAL ENERGY COSTS | $413,351 | |||
RECOMMENDED SAVINGS* | $43,274 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,873 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,921 Cost: $1,311 |
$1,763 | 32,825 | $158 | 79 | - | - | - | - |
$1,763 32,825 kWh |
$158 79 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,159 Cost: $5,364 |
$1,968 | 36,635 | $191 | 96 | - | - | - | - |
$1,968 36,635 kWh |
$191 96 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $95 Cost: - |
$90 | 1,758 | $5 | 2 | - | - | - | - |
$90 1,758 kWh |
$5 2 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,967 Cost: $9,063 |
$5,561 | 103,165 | $406 | 204 | - | - | - | - |
$5,561 103,165 kWh |
$406 204 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,057 Cost: - |
$988 | 18,464 | $69 | 35 | - | - | - | - |
$988 18,464 kWh |
$69 35 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,587 Cost: $50 |
$3,355 | 62,427 | $232 | 116 | - | - | - | - |
$3,355 62,427 kWh |
$232 116 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,341 Cost: $263 |
$3,124 | 58,030 | $217 | 109 | - | - | - | - |
$3,124 58,030 kWh |
$217 109 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,650 Cost: $140 |
$1,542 | 28,722 | $108 | 54 | - | - | - | - |
$1,542 28,722 kWh |
$108 54 kW-months/year |
- - MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $16,497 Cost: $41,242 |
- | - | - | - | $16,497 | 4,411 | - | - |
- - kWh |
- - kW-months/year |
$16,497 4,411 MMBtu |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.1163 USE PLASTIC PALLETS INSTEAD OF WOOD |
Savings: $7,000 Cost: $20,000 |
- | - | - | - | - | - | $7,000 | 20,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$7,000 20,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $43,274 Cost: $77,433 |
$18,391 | 342,026 | $1,386 | 695 | $16,497 | 4,411 | $7,000 | 20,000 | $18,391 342,026 kWh |
$1,386 695 kW-months/year |
$16,497 4,411 MMBtu |
$7,000 20,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,873 Cost: $30,687 |
$14,791 | 274,911 | $1,082 | 543 | - | - | $7,000 | 20,000 | $14,791 274,911 kWh |
$1,082 543 kW-months/year |
- - MMBtu |
$7,000 20,000 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) |