Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1996 |
Principal Product | Aluminum Extrusions |
NAICS | n/a |
SIC | 3334 - Primary Aluminum |
Sales | $10,000,000-$50,000,000 |
# of Employees | 169 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 18,000,000 Pounds |
Production Hrs. Annual | 4,000 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $383,443 | 7,648,593 | kWh | $0.05 |
Electricity Demand | $43,923 | 20,333 | kW-months/year | $2.16 |
Natural Gas | $591,304 | 162,342 | MMBtu | $3.64 |
TOTAL ENERGY COSTS | $1,028,401 | |||
RECOMMENDED SAVINGS* | $17,356 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,410 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Electricity Usage | Electricity Demand | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $981 Cost: $1,097 |
$886 | 15,826 | $95 | 48 | - | - |
$886 15,826 kWh |
$95 48 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,872 Cost: $3,120 |
$1,691 | 30,481 | $181 | 91 | - | - |
$1,691 30,481 kWh |
$181 91 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,350 Cost: - |
$1,257 | 22,567 | $93 | 47 | - | - |
$1,257 22,567 kWh |
$93 47 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $10,105 Cost: $19,207 |
$9,425 | 169,402 | $680 | 343 | - | - |
$9,425 169,402 kWh |
$680 343 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,102 Cost: $460 |
$996 | 17,878 | $106 | 54 | - | - |
$996 17,878 kWh |
$106 54 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1242 ALLOW DRAINAGE BEFORE WITHDRAWING OBJECT |
Savings: $1,946 Cost: - |
- | - | - | - | $1,946 | 936 |
- - kWh |
- - kW-months/year |
$1,946 936 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $17,356 Cost: $23,884 |
$14,255 | 256,154 | $1,155 | 583 | $1,946 | 936 | $14,255 256,154 kWh |
$1,155 583 kW-months/year |
$1,946 936 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,410 Cost: $23,884 |
$14,255 | 256,154 | $1,155 | 583 | - | - | $14,255 256,154 kWh |
$1,155 583 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Electricity Usage | Electricity Demand | Other Liquid (haz) |