Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1996 |
Principal Product | Business Forms Printing |
NAICS | n/a |
SIC | 2761 - Manifold Business Forms |
Sales | $50,000,000-$100,000,000 |
# of Employees | 270 |
Plant Area (Sq.Ft.) | 75,000 |
Annual Production | 22,849 Tons |
Production Hrs. Annual | 8,400 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $338,121 | 7,948,711 | kWh | $0.04 |
Electricity Demand | $27,034 | 15,096 | kW-months/year | $1.79 |
Natural Gas | $24,709 | 6,136 | MMBtu | $4.03 |
TOTAL ENERGY COSTS | $396,076 | |||
RECOMMENDED SAVINGS* | $48,644 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $45,137 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Gaseous Waste | Electricity Usage | Electricity Demand | Gaseous Waste | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,830 Cost: $6,997 |
$6,491 | 137,749 | $339 | 211 | - | - |
$6,491 137,749 kWh |
$339 211 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $11,517 Cost: $20,272 |
$10,922 | 231,536 | $595 | 371 | - | - |
$10,922 231,536 kWh |
$595 371 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $298 Cost: - |
$285 | 6,155 | $13 | 8 | - | - |
$285 6,155 kWh |
$13 8 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $7,894 Cost: - |
$7,486 | 158,851 | $408 | 254 | - | - |
$7,486 158,851 kWh |
$408 254 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $17,021 Cost: $27,890 |
$16,135 | 342,321 | $886 | 552 | - | - |
$16,135 342,321 kWh |
$886 552 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,577 Cost: $90 |
$1,504 | 31,946 | $73 | 46 | - | - |
$1,504 31,946 kWh |
$73 46 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $3,507 Cost: - |
- | - | - | - | $3,507 | 5,010 |
- - kWh |
- - kW-months/year |
$3,507 5,010 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $48,644 Cost: $55,249 |
$42,823 | 908,558 | $2,314 | 1,442 | $3,507 | 5,010 | $42,823 908,558 kWh |
$2,314 1,442 kW-months/year |
$3,507 5,010 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $45,137 Cost: $55,249 |
$42,823 | 908,558 | $2,314 | 1,442 | - | - | $42,823 908,558 kWh |
$2,314 1,442 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Gaseous Waste | Electricity Usage | Electricity Demand | Gaseous Waste |