Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1997 |
Principal Product | Food Service Equipment |
NAICS | n/a |
SIC | 3430 - |
Sales | $10,000,000-$50,000,000 |
# of Employees | 157 |
Plant Area (Sq.Ft.) | 62,500 |
Annual Production | 192,000 Pieces |
Production Hrs. Annual | 6,292 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $63,826 | 1,427,022 | kWh | $0.04 |
Electricity Demand | $8,994 | 286 | kW-months/year | $31.45 |
Electricity Fees | $8,994 | - | $ | - |
Natural Gas | $17,082 | 2,981 | MMBtu | $5.73 |
TOTAL ENERGY COSTS | $169,204 | |||
RECOMMENDED SAVINGS* | $90,531 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $34,066 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $5,391 Cost: $3,500 |
- | - | - | - | - | - | - | - | $5,391 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
$5,391 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $5,000 Cost: $12,500 |
- | - | - | - | - | - | - | - | $5,000 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
$5,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $780 Cost: $2,032 |
$687 | 13,482 | $93 | 4 | - | - | - | - | - | - |
$687 13,482 kWh |
$93 4 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,526 Cost: $1,222 |
$6,011 | 117,819 | $515 | 19 | - | - | - | - | - | - |
$6,011 117,819 kWh |
$515 19 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $144 Cost: $276 |
$136 | 2,638 | $8 | 1 | - | - | - | - | - | - |
$136 2,638 kWh |
$8 1 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $541 Cost: $40 |
$464 | 9,086 | $77 | 3 | - | - | - | - | - | - |
$464 9,086 kWh |
$77 3 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $553 Cost: $50 |
$473 | 9,379 | $80 | 3 | - | - | - | - | - | - |
$473 9,379 kWh |
$80 3 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,288 Cost: $1,976 |
$1,171 | 22,860 | $117 | 4 | - | - | - | - | - | - |
$1,171 22,860 kWh |
$117 4 kW-months/year |
- - gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $55,000 Cost: $85,000 |
- | - | - | - | $55,000 | 30,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$55,000 30,000 gal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $15,308 Cost: $4,860 |
- | - | - | - | - | - | $15,308 | 325,000 | - | - |
- - kWh |
- - kW-months/year |
- - gal |
$15,308 325,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $90,531 Cost: $111,456 |
$8,942 | 175,264 | $890 | 34 | $55,000 | 30,000 | $15,308 | 325,000 | $10,391 | - | $8,942 175,264 kWh |
$890 34 kW-months/year |
$55,000 30,000 gal |
$15,308 325,000 lb |
$10,391 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $34,066 Cost: $24,108 |
$7,655 | 150,058 | $712 | 26 | - | - | $15,308 | 325,000 | $10,391 | - | $7,655 150,058 kWh |
$712 26 kW-months/year |
- - gal |
$15,308 325,000 lb |
$10,391 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (non-haz) | Ancillary Material Cost |