IAC logo
IAC Assessment: MO0253
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MO0253
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri, Rolla
Assessment Year 1999
Principal Product Bearings and Bushings
NAICS n/a
SIC 3568 - Power Transmission Equipment, Nec
Sales $5,000,000-$10,000,000
# of Employees 92
Plant Area (Sq.Ft.) 41,500
Annual Production 300,000 Pieces
Production Hrs. Annual 6,000
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $97,096 2,789,273 kWh $0.03
Electricity Demand $26,823 499 kW-months/year $53.75
Electricity Fees $15,448 - $ -
Natural Gas $47,037 8,065 MMBtu $5.83
TOTAL ENERGY COSTS $189,168
RECOMMENDED SAVINGS* $88,818 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $22,901
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Administrative Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$4,142
Cost:
$5,326
$3,336 82,649 $806 15 - - - - $3,336
82,649
kWh
$806
15
kW-months/year
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,507
Cost:
$5,843
$2,023 50,117 $484 9 - - - - $2,023
50,117
kWh
$484
9
kW-months/year
-
-
$
-
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,044
Cost:
$40
$1,668 41,325 $376 7 - - - - $1,668
41,325
kWh
$376
7
kW-months/year
-
-
$
-
-
$
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,393
Cost:
$58
$1,124 27,843 $269 5 - - - - $1,124
27,843
kWh
$269
5
kW-months/year
-
-
$
-
-
$
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,322
Cost:
-
$1,053 26,084 $269 5 - - - - $1,053
26,084
kWh
$269
5
kW-months/year
-
-
$
-
-
$
06: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$63,081
Cost:
$12,600
- - - - - - $63,081 - -
-
kWh
-
-
kW-months/year
-
-
$
$63,081
-
$
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$14,000
Cost:
$3,700
- - - - - - $14,000 - -
-
kWh
-
-
kW-months/year
-
-
$
$14,000
-
$
08: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$329
Cost:
$714
- - - - $329 - - - -
-
kWh
-
-
kW-months/year
$329
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$88,818
Cost:
$28,281
$9,204 228,018 $2,204 41 $329 - $77,081 - $9,204
228,018
kWh
$2,204
41
kW-months/year
$329
-
$
$77,081
-
$
TOTAL IMPLEMENTED Savings:
$22,901
Cost:
$9,124
$7,181 177,901 $1,720 32 - - $14,000 - $7,181
177,901
kWh
$1,720
32
kW-months/year
-
-
$
$14,000
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Administrative Changes Ancillary Material Cost