Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1999 |
Principal Product | Jacketed Rifle and Pistol Projectiles |
NAICS | n/a |
SIC | 3482 - Small Arms Ammunition |
Sales | $10,000,000-$50,000,000 |
# of Employees | 84 |
Plant Area (Sq.Ft.) | 43,000 |
Annual Production | 116,200,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $72,287 | 1,648,007 | kWh | $0.04 |
Electricity Demand | $10,354 | 418 | kW-months/year | $24.77 |
Electricity Fees | $11,846 | - | $ | - |
Natural Gas | $29,630 | 5,219 | MMBtu | $5.68 |
TOTAL ENERGY COSTS | $135,770 | |||
RECOMMENDED SAVINGS* | $73,210 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $67,918 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,911 Cost: $4,897 |
$3,584 | 70,340 | $327 | 13 | - | - | - | - |
$3,584 70,340 kWh |
$327 13 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,257 Cost: $3,392 |
$2,009 | 39,273 | $248 | 10 | - | - | - | - |
$2,009 39,273 kWh |
$248 10 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,116 Cost: $49 |
$1,032 | 20,223 | $84 | 3 | - | - | - | - |
$1,032 20,223 kWh |
$84 3 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,256 Cost: $40 |
$1,162 | 22,860 | $94 | 4 | - | - | - | - |
$1,162 22,860 kWh |
$94 4 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $1,750 Cost: $450 |
$1,668 | 19,637 | $82 | 3 | - | - | - | - |
$1,668 19,637 kWh |
$82 3 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $2,460 Cost: - |
- | - | - | - | $2,460 | 12,750 | - | - |
- - kWh |
- - kW-months/year |
$2,460 12,750 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $60,000 Cost: $27,500 |
- | - | - | - | - | - | $60,000 | - |
- - kWh |
- - kW-months/year |
- - lb |
$60,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $460 Cost: $345 |
$165 | 3,224 | $10 | 1 | - | - | $285 | - |
$165 3,224 kWh |
$10 1 kW-months/year |
- - lb |
$285 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $73,210 Cost: $36,673 |
$9,620 | 175,557 | $845 | 34 | $2,460 | 12,750 | $60,285 | - | $9,620 175,557 kWh |
$845 34 kW-months/year |
$2,460 12,750 lb |
$60,285 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $67,918 Cost: $36,239 |
$7,261 | 129,250 | $657 | 26 | - | - | $60,000 | - | $7,261 129,250 kWh |
$657 26 kW-months/year |
- - lb |
$60,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes |