Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri, Rolla |
---|---|
Assessment Year | 1999 |
Principal Product | Iron Oxide Pigments |
NAICS | n/a |
SIC | 2816 - Inorganic Pigments |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 210,000 |
Annual Production | 38,000,000 Pounds |
Production Hrs. Annual | 5,320 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $616,287 | 15,273,447 | kWh | $0.04 |
Electricity Demand | $43,247 | 2,141 | kW-months/year | $20.20 |
Electricity Fees | $67,205 | - | $ | - |
Natural Gas | $759,510 | 368,477 | MMBtu | $2.06 |
TOTAL ENERGY COSTS | $2,154,566 | |||
RECOMMENDED SAVINGS* | $46,103 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,340 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,048 Cost: $3,071 |
$905 | 20,223 | $143 | 7 | - | - | - | - | - | - |
$905 20,223 kWh |
$143 7 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $27,744 Cost: $41,879 |
$25,558 | 570,633 | $2,186 | 108 | - | - | - | - | - | - |
$25,558 570,633 kWh |
$2,186 108 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,759 Cost: - |
$3,460 | 77,374 | $299 | 15 | - | - | - | - | - | - |
$3,460 77,374 kWh |
$299 15 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.1175 USE A DIFFERENT OR RECYCLED RAW MATERIAL |
Savings: $700 Cost: - |
- | - | - | - | $700 | 350 | - | - | - | - |
- - kWh |
- - kW-months/year |
$700 350 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $9,212 Cost: - |
- | - | - | - | - | - | - | - | $9,212 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$9,212 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $3,640 Cost: $3,700 |
- | - | - | - | - | - | $3,640 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$3,640 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $46,103 Cost: $48,650 |
$29,923 | 668,230 | $2,628 | 130 | $700 | 350 | $3,640 | - | $9,212 | - | $29,923 668,230 kWh |
$2,628 130 kW-months/year |
$700 350 lb |
$3,640 - $ |
$9,212 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,340 Cost: $3,700 |
- | - | - | - | $700 | 350 | $3,640 | - | - | - | - - kWh |
- - kW-months/year |
$700 350 lb |
$3,640 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost |