Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 1998 |
Principal Product | Battery Components |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 12,500,000 Pounds |
Production Hrs. Annual | 7,344 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $512,246 | 16,691,970 | kWh | $0.03 |
Electricity Demand | $298,526 | 32,172 | kW-months/year | $9.28 |
Electricity Fees | $14,476 | - | $ | - |
Natural Gas | $43,357 | 8,226 | MMBtu | $5.27 |
TOTAL ENERGY COSTS | $894,195 | |||
RECOMMENDED SAVINGS* | $110,363 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,432 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,208 Cost: $9,250 |
$6,244 | 204,865 | $3,813 | 398 | $151 | - | - | - | - | - |
$6,244 204,865 kWh |
$3,813 398 kW-months/year |
$151 - $ |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,045 Cost: $8,030 |
$3,986 | 130,715 | - | - | $59 | - | - | - | - | - |
$3,986 130,715 kWh |
- - kW-months/year |
$59 - $ |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $10,852 Cost: $7,236 |
$10,692 | 350,821 | - | - | $160 | - | - | - | - | - |
$10,692 350,821 kWh |
- - kW-months/year |
$160 - $ |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $11,323 Cost: $4,875 |
- | - | - | - | $11,323 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$11,323 - $ |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $70,934 Cost: $513,675 |
$67,021 | 2,198,124 | $2,864 | 299 | $1,049 | - | - | - | - | - |
$67,021 2,198,124 kWh |
$2,864 299 kW-months/year |
$1,049 - $ |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $1,049 Cost: $1,235 |
- | - | - | - | - | - | - | - | $1,049 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - gal |
$1,049 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6124 BURN WASTE OIL FOR HEAT |
Savings: $1,952 Cost: $2,745 |
$1,430 | 46,893 | - | - | $22 | - | $500 | 2,700 | - | - |
$1,430 46,893 kWh |
- - kW-months/year |
$22 - $ |
$500 2,700 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $110,363 Cost: $547,046 |
$89,373 | 2,931,418 | $6,677 | 697 | $12,764 | - | $500 | 2,700 | $1,049 | - | $89,373 2,931,418 kWh |
$6,677 697 kW-months/year |
$12,764 - $ |
$500 2,700 gal |
$1,049 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,432 Cost: $22,596 |
$16,936 | 555,686 | $3,813 | 398 | $11,634 | - | - | - | $1,049 | - | $16,936 555,686 kWh |
$3,813 398 kW-months/year |
$11,634 - $ |
- - gal |
$1,049 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (haz) | Ancillary Material Cost |