Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Mississippi State |
---|---|
Assessment Year | 2005 |
Principal Product | Veneer |
NAICS | 321211 - Hardwood Veneer and Plywood Manufacturing |
SIC | 2435 - Hardwood Veneer And Plywood |
Sales | $10,000,000-$50,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 232,000 |
Annual Production | 5,700 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | MS |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $147,982 | 3,318,084 | kWh | $0.04 |
Electricity Demand | $34,329 | 10,654 | kW-months/year | $3.22 |
Electricity Fees | $66,024 | - | $ | - |
TOTAL ENERGY COSTS | $248,335 | |||
RECOMMENDED SAVINGS* | $244,736 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3414 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT |
Savings: $219,363 Cost: $472,500 |
$311,155 | 6,991,920 | $32,934 | 16,200 | $114,474 | - | $(-239,200) | - |
$311,155 6,991,920 kWh |
$32,934 16,200 kW-months/year |
$114,474 - $ |
$(-239,200) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,947 Cost: $22,298 |
$7,245 | 169,126 | $1,038 | 325 | $2,664 | - | - | - |
$7,245 169,126 kWh |
$1,038 325 kW-months/year |
$2,664 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $6,573 Cost: $11,233 |
$4,188 | 97,775 | $802 | 251 | $1,583 | - | - | - |
$4,188 97,775 kWh |
$802 251 kW-months/year |
$1,583 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,467 Cost: $4,140 |
$1,543 | 36,027 | $332 | 104 | $592 | - | - | - |
$1,543 36,027 kWh |
$332 104 kW-months/year |
$592 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,337 Cost: $7,721 |
$1,545 | 36,060 | $224 | 70 | $568 | - | - | - |
$1,545 36,060 kWh |
$224 70 kW-months/year |
$568 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,990 Cost: $203 |
$1,488 | 34,739 | - | - | $502 | - | - | - |
$1,488 34,739 kWh |
- - kW-months/year |
$502 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,059 Cost: $236 |
$792 | 18,498 | - | - | $267 | - | - | - |
$792 18,498 kWh |
- - kW-months/year |
$267 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $244,736 Cost: $518,331 |
$327,956 | 7,384,145 | $35,330 | 16,950 | $120,650 | - | $(-239,200) | - | $327,956 7,384,145 kWh |
$35,330 16,950 kW-months/year |
$120,650 - $ |
$(-239,200) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost |