Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 1996 |
Principal Product | Magnet Wire |
NAICS | n/a |
SIC | 3357 - Nonferrous Wiredrawing & Insulating |
Sales | $10,000,000-$50,000,000 |
# of Employees | 170 |
Plant Area (Sq.Ft.) | 179,000 |
Annual Production | 100,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $508,946 | 20,041,618 | kWh | $0.03 |
Electricity Demand | $515,305 | 31,087 | kW-months/year | $16.58 |
Electricity Fees | $23,870 | - | $ | - |
Natural Gas | $112,200 | 29,243 | MMBtu | $3.84 |
TOTAL ENERGY COSTS | $1,167,455 | |||
RECOMMENDED SAVINGS* | $40,041 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $31,379 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (haz) | Personnel Changes | Electricity Usage | Electricity Demand | Solid Waste (haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,648 Cost: $6,993 |
$1,361 | 53,048 | $1,287 | 80 | - | - | - | - |
$1,361 53,048 kWh |
$1,287 80 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,528 Cost: $1,530 |
$333 | 12,896 | $284 | 18 | - | - | $911 | - |
$333 12,896 kWh |
$284 18 kW-months/year |
- - lb |
$911 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $14,370 Cost: $7,500 |
$14,370 | 560,082 | - | - | - | - | - | - |
$14,370 560,082 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $5,344 Cost: - |
$1,499 | 58,324 | $3,845 | 240 | - | - | - | - |
$1,499 58,324 kWh |
$3,845 240 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4312 IMPROVE LUBRICATION PRACTICES |
Savings: $9,017 Cost: $20,000 |
$3,833 | 162,075 | $5,184 | 324 | - | - | - | - |
$3,833 162,075 kWh |
$5,184 324 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.3125 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS |
Savings: $7,134 Cost: $25,000 |
- | - | - | - | $7,134 | 4,000 | - | - |
- - kWh |
- - kW-months/year |
$7,134 4,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $40,041 Cost: $61,023 |
$21,396 | 846,425 | $10,600 | 662 | $7,134 | 4,000 | $911 | - | $21,396 846,425 kWh |
$10,600 662 kW-months/year |
$7,134 4,000 lb |
$911 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $31,379 Cost: $34,493 |
$21,063 | 833,529 | $10,316 | 644 | - | - | - | - | $21,063 833,529 kWh |
$10,316 644 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (haz) | Personnel Changes | Electricity Usage | Electricity Demand | Solid Waste (haz) | Personnel Changes |