IAC logo
IAC Assessment: NC0155
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: NC0155
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 1998
Principal Product Industrial fabric
NAICS n/a
SIC 2228 -
Sales $10,000,000-$50,000,000
# of Employees 350
Plant Area (Sq.Ft.) 600,000
Annual Production 120,000 Thousand Feet
Production Hrs. Annual 8,700
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $652,161 24,804,221 kWh $0.03
Electricity Demand $340,261 35,115 kW-months/year $9.69
Natural Gas $470,599 107,498 MMBtu $4.38
TOTAL ENERGY COSTS $1,463,021
RECOMMENDED SAVINGS* $71,913 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas By-product Production Electricity Usage Electricity Demand Natural Gas By-product Production
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$109
Cost:
-
- - $109 12 - - - - -
-
kWh
$109
12
kW-months/year
-
-
MMBtu
-
-
$
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$2,802
Cost:
$700
- - - - $2,802 907 - - -
-
kWh
-
-
kW-months/year
$2,802
907
MMBtu
-
-
$
03: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE Savings:
$441
Cost:
$50
$441 16,999 - - - - - - $441
16,999
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$386
Cost:
-
$270 10,258 $116 12 - - - - $270
10,258
kWh
$116
12
kW-months/year
-
-
MMBtu
-
-
$
05: 2.7229 AIR CONDITION ONLY SPACE NECESSARY Savings:
$3,045
Cost:
$5,426
$2,079 65,064 $966 103 - - - - $2,079
65,064
kWh
$966
103
kW-months/year
-
-
MMBtu
-
-
$
06: 2.2532 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD Savings:
$15,130
Cost:
$9,000
$3,945 150,059 $2,826 300 $8,359 1,821 - - $3,945
150,059
kWh
$2,826
300
kW-months/year
$8,359
1,821
MMBtu
-
-
$
07: 4.5210 CLEAR AND RENT EXISTING SPACE Savings:
$50,000
Cost:
$150,000
- - - - - - $50,000 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$50,000
-
$
TOTAL RECOMMENDED Savings:
$71,913
Cost:
$165,176
$6,735 242,380 $4,017 427 $11,161 2,728 $50,000 - $6,735
242,380
kWh
$4,017
427
kW-months/year
$11,161
2,728
MMBtu
$50,000
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas By-product Production Electricity Usage Electricity Demand Natural Gas By-product Production