Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2000 |
Principal Product | Denim fabric |
NAICS | n/a |
SIC | 2321 - Men's and Boys' Shirts, Except Work Shirts |
Sales | $50,000,000-$100,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 45,000 Thousand Feet |
Production Hrs. Annual | 8,760 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $529,790 | 22,447,832 | kWh | $0.02 |
Electricity Demand | $650,320 | 40,306 | kW-months/year | $16.13 |
Electricity Fees | $62,145 | - | $ | - |
Natural Gas | $607,782 | 128,616 | MMBtu | $4.73 |
TOTAL ENERGY COSTS | $1,850,037 | |||
RECOMMENDED SAVINGS* | $183,646 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $172,702 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $150,957 Cost: $214,000 |
$(-1,147) | (-48,652) | $(-1,119) | (-72) | $158,516 | 35,226 | $(-5,293) | (-998,640) |
$(-1,147) (-48,652) kWh |
$(-1,119) (-72) kW-months/year |
$158,516 35,226 MMBtu |
$(-5,293) (-998,640) Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,306 Cost: $300 |
$3,785 | 160,317 | $3,521 | 220 | - | - | - | - |
$3,785 160,317 kWh |
$3,521 220 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7122 DISCONNECT BALLASTS |
Savings: $7,600 Cost: $6,350 |
$3,938 | 167,057 | $3,662 | 229 | - | - | - | - |
$3,938 167,057 kWh |
$3,662 229 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,637 Cost: $7,260 |
$734 | 31,067 | $1,903 | 119 | - | - | - | - |
$734 31,067 kWh |
$1,903 119 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $6,839 Cost: $3,180 |
$3,648 | 154,748 | $3,191 | 199 | - | - | - | - |
$3,648 154,748 kWh |
$3,191 199 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,675 Cost: $50 |
$1,904 | 80,598 | $1,771 | 111 | - | - | - | - |
$1,904 80,598 kWh |
$1,771 111 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR |
Savings: $4,632 Cost: $7,499 |
$(-59) | (-2,345) | - | - | $4,691 | 992 | - | - |
$(-59) (-2,345) kWh |
- - kW-months/year |
$4,691 992 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $183,646 Cost: $238,639 |
$12,803 | 542,790 | $12,929 | 806 | $163,207 | 36,218 | $(-5,293) | (-998,640) | $12,803 542,790 kWh |
$12,929 806 kW-months/year |
$163,207 36,218 MMBtu |
$(-5,293) (-998,640) Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $172,702 Cost: $223,830 |
$10,224 | 433,470 | $9,255 | 576 | $158,516 | 35,226 | $(-5,293) | (-998,640) | $10,224 433,470 kWh |
$9,255 576 kW-months/year |
$158,516 35,226 MMBtu |
$(-5,293) (-998,640) Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |