IAC logo
IAC Assessment: NC0198
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: NC0198
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 2000
Principal Product Grounding rods
NAICS n/a
SIC 3699 - Electrical Equipment & Supplies, Nec
Sales $10,000,000-$50,000,000
# of Employees 90
Plant Area (Sq.Ft.) 225,000
Annual Production 6,000,000 Pieces
Production Hrs. Annual 8,760
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $662,449 22,570,047 kWh $0.03
Electricity Demand $328,104 39,435 kW-months/year $8.32
Electricity Fees $4,803 - $ -
Natural Gas $49,378 7,813 MMBtu $6.32
TOTAL ENERGY COSTS $1,044,734
RECOMMENDED SAVINGS* $64,814 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,557
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas
$ kWh $ kW-months/year $ $ $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,448
Cost:
$300
$1,749 60,375 $699 83 - - - - $1,749
60,375
kWh
$699
83
kW-months/year
-
-
$
-
-
MMBtu
02: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$9,807
Cost:
$18,000
$6,907 238,277 $2,900 343 - - - - $6,907
238,277
kWh
$2,900
343
kW-months/year
-
-
$
-
-
MMBtu
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$19,308
Cost:
$41,718
- - - - - - $19,308 3,055 -
-
kWh
-
-
kW-months/year
-
-
$
$19,308
3,055
MMBtu
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$4,264
Cost:
-
- - $3,448 408 $816 - - - -
-
kWh
$3,448
408
kW-months/year
$816
-
$
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,845
Cost:
$820
- - - - - - $1,845 292 -
-
kWh
-
-
kW-months/year
-
-
$
$1,845
292
MMBtu
06: 2.9112 USE SOLAR HEAT TO HEAT WATER Savings:
$27,142
Cost:
$97,350
$12,338 425,557 $14,804 1,752 - - - - $12,338
425,557
kWh
$14,804
1,752
kW-months/year
-
-
$
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$64,814
Cost:
$158,188
$20,994 724,209 $21,851 2,586 $816 - $21,153 3,347 $20,994
724,209
kWh
$21,851
2,586
kW-months/year
$816
-
$
$21,153
3,347
MMBtu
TOTAL IMPLEMENTED Savings:
$8,557
Cost:
$1,120
$1,749 60,375 $4,147 491 $816 - $1,845 292 $1,749
60,375
kWh
$4,147
491
kW-months/year
$816
-
$
$1,845
292
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu
Electricity Usage Electricity Demand Electricity Fees Natural Gas Electricity Usage Electricity Demand Electricity Fees Natural Gas