Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2001 |
Principal Product | Knitted fabric |
NAICS | n/a |
SIC | 2253 - Knit Outerwear Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 125,804 |
Annual Production | 13,500,000 Pounds |
Production Hrs. Annual | 8,488 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $104,499 | 3,628,440 | kWh | $0.03 |
Electricity Demand | $79,397 | 9,284 | kW-months/year | $8.55 |
LPG | $7,772 | 914 | MMBtu | $8.50 |
TOTAL ENERGY COSTS | $193,243 | |||
RECOMMENDED SAVINGS* | $11,249 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,568 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $2,845 Cost: $5,600 |
$1,282 | 44,525 | $(-137) | (-17) | $1,700 | 200 | - | - | - | - |
$1,282 44,525 kWh |
$(-137) (-17) kW-months/year |
$1,700 200 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $2,519 Cost: $5,600 |
$2,519 | 87,480 | - | - | - | - | - | - | - | - |
$2,519 87,480 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,161 Cost: $5,700 |
$2,131 | 74,003 | $1,030 | 124 | - | - | - | - | - | - |
$2,131 74,003 kWh |
$1,030 124 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $163 Cost: $200 |
$111 | 3,851 | $52 | 6 | - | - | - | - | - | - |
$111 3,851 kWh |
$52 6 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,886 Cost: $2,360 |
$335 | 11,644 | $163 | 19 | - | - | - | - | $1,388 | - |
$335 11,644 kWh |
$163 19 kW-months/year |
- - MMBtu |
- - lb |
$1,388 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $675 Cost: $200 |
- | - | - | - | - | - | $675 | 90,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$675 90,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $11,249 Cost: $19,660 |
$6,378 | 221,503 | $1,108 | 132 | $1,700 | 200 | $675 | 90,000 | $1,388 | - | $6,378 221,503 kWh |
$1,108 132 kW-months/year |
$1,700 200 MMBtu |
$675 90,000 lb |
$1,388 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,568 Cost: $8,160 |
$2,965 | 102,975 | $215 | 25 | - | - | - | - | $1,388 | - | $2,965 102,975 kWh |
$215 25 kW-months/year |
- - MMBtu |
- - lb |
$1,388 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Administrative Changes |