Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2001 |
Principal Product | Irrigation equipment |
NAICS | n/a |
SIC | 3432 - Plumbing Fixture Fittings And Trim |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 83,000 |
Annual Production | 1,000,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $158,839 | 5,205,750 | kWh | $0.03 |
Electricity Demand | $89,580 | 10,625 | kW-months/year | $8.43 |
Electricity Fees | $7,041 | - | $ | - |
Natural Gas | $25,502 | 3,315 | MMBtu | $7.69 |
TOTAL ENERGY COSTS | $282,612 | |||
RECOMMENDED SAVINGS* | $41,254 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,685 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $5,685 Cost: $25 |
- | - | - | - | $5,685 | 688 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,685 688 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $5,740 Cost: $5,000 |
$4,685 | 152,607 | $2,545 | 305 | - | - | $(-950) | (-215,827) | - | - | - | - | $(-540) | - |
$4,685 152,607 kWh |
$2,545 305 kW-months/year |
- - MMBtu |
$(-950) (-215,827) Tgal |
- - lb |
- - $ |
$(-540) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2623 MINIMIZE CONDENSER COOLING WATER TEMPERATURE |
Savings: $2,554 Cost: $11,000 |
$6,351 | 206,873 | $4,007 | 468 | - | - | $(-4,976) | (-1,131,000) | - | - | - | - | $(-2,828) | - |
$6,351 206,873 kWh |
$4,007 468 kW-months/year |
- - MMBtu |
$(-4,976) (-1,131,000) Tgal |
- - lb |
- - $ |
$(-2,828) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM |
Savings: $1,456 Cost: $800 |
$129 | 4,200 | $266 | 29 | $1,061 | 138 | - | - | - | - | - | - | - | - |
$129 4,200 kWh |
$266 29 kW-months/year |
$1,061 138 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $3,300 Cost: $5,000 |
$2,138 | 69,644 | $1,162 | 139 | - | - | - | - | - | - | - | - | - | - |
$2,138 69,644 kWh |
$1,162 139 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $392 Cost: $120 |
$254 | 8,280 | $138 | 17 | - | - | - | - | - | - | - | - | - | - |
$254 8,280 kWh |
$138 17 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,001 Cost: $1,589 |
$648 | 21,112 | $353 | 42 | - | - | - | - | - | - | - | - | - | - |
$648 21,112 kWh |
$353 42 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $6,950 Cost: $8,846 |
- | - | - | - | $6,950 | 904 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,950 904 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $12,215 Cost: $18,300 |
$7,911 | 257,700 | $4,304 | 515 | - | - | - | - | - | - | - | - | - | - |
$7,911 257,700 kWh |
$4,304 515 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,136 Cost: $2,093 |
$736 | 23,959 | $400 | 48 | - | - | - | - | - | - | - | - | - | - |
$736 23,959 kWh |
$400 48 kW-months/year |
- - MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $825 Cost: - |
- | - | - | - | - | - | - | - | $1,650 | 54,000 | $(-825) | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$1,650 54,000 lb |
$(-825) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $41,254 Cost: $52,773 |
$22,852 | 744,375 | $13,175 | 1,563 | $13,696 | 1,730 | $(-5,926) | (-1,346,827) | $1,650 | 54,000 | $(-825) | - | $(-3,368) | - | $22,852 744,375 kWh |
$13,175 1,563 kW-months/year |
$13,696 1,730 MMBtu |
$(-5,926) (-1,346,827) Tgal |
$1,650 54,000 lb |
$(-825) - $ |
$(-3,368) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,685 Cost: $25 |
- | - | - | - | $5,685 | 688 | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
$5,685 688 MMBtu |
- - Tgal |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Ancillary Material Cost |