Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2001 |
Principal Product | Feldspar |
NAICS | n/a |
SIC | 3299 - Nonmetallic Mineral Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 31 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 440,000,000 Pounds |
Production Hrs. Annual | 8,600 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $387,604 | 9,590,208 | kWh | $0.04 |
Electricity Demand | $139,948 | 17,773 | kW-months/year | $7.87 |
Fuel Oil #4 | $301,000 | 95,200 | MMBtu | $3.16 |
TOTAL ENERGY COSTS | $828,552 | |||
RECOMMENDED SAVINGS* | $169,776 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $111,660 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #4 | Administrative Changes | Electricity Usage | Electricity Demand | Fuel Oil #4 | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $272 Cost: $450 |
$214 | 5,307 | $58 | 7 | - | - | - | - |
$214 5,307 kWh |
$58 7 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4154 AVOID REWINDING MOTORS MORE THAN TWICE |
Savings: $8,087 Cost: $6,437 |
$6,362 | 157,487 | $1,725 | 220 | - | - | - | - |
$6,362 157,487 kWh |
$1,725 220 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,084 Cost: $1,559 |
$3,213 | 79,530 | $871 | 111 | - | - | - | - |
$3,213 79,530 kWh |
$871 111 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $44,656 Cost: $40,000 |
- | - | - | - | $44,656 | 13,955 | - | - |
- - kWh |
- - kW-months/year |
$44,656 13,955 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $13,013 Cost: $35,000 |
$15,209 | 376,450 | $4,286 | 546 | $(-5,482) | (-1,713) | $(-1,000) | - |
$15,209 376,450 kWh |
$4,286 546 kW-months/year |
$(-5,482) (-1,713) MMBtu |
$(-1,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $9,104 Cost: $17,000 |
- | - | - | - | $9,104 | 2,817 | - | - |
- - kWh |
- - kW-months/year |
$9,104 2,817 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $90,560 Cost: $35,000 |
- | - | $90,560 | - | - | - | - | - |
- - kWh |
$90,560 - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $169,776 Cost: $135,446 |
$24,998 | 618,774 | $97,500 | 884 | $48,278 | 15,059 | $(-1,000) | - | $24,998 618,774 kWh |
$97,500 884 kW-months/year |
$48,278 15,059 MMBtu |
$(-1,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $111,660 Cost: $76,437 |
$21,571 | 533,937 | $96,571 | 766 | $(-5,482) | (-1,713) | $(-1,000) | - | $21,571 533,937 kWh |
$96,571 766 kW-months/year |
$(-5,482) (-1,713) MMBtu |
$(-1,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #4 | Administrative Changes | Electricity Usage | Electricity Demand | Fuel Oil #4 | Administrative Changes |