Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 2001
Principal Product Wood cabinets and doors
NAICS n/a
SIC 2431 - Millwork
Sales $10,000,000-$50,000,000
# of Employees 115
Plant Area (Sq.Ft.) 125,000
Annual Production 5,500,000 Pounds
Production Hrs. Annual 2,000
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $72,110 1,302,800 kWh $0.06
Electricity Demand $58,962 7,946 kW-months/year $7.42
Electricity Fees $5,089 - $ -
TOTAL ENERGY COSTS $136,161
RECOMMENDED SAVINGS* $18,124 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,000
#|Description Savings
Cost
Status Electricity Usage Electricity Demand By-product Production Electricity Usage Electricity Demand By-product Production
$ kWh $ kW-months/year $ $
01: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$1,083
Cost:
$25
$591 11,040 $492 66 - - $591
11,040
kWh
$492
66
kW-months/year
-
-
$
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$751
Cost:
$525
$751 14,035 - - - - $751
14,035
kWh
-
-
kW-months/year
-
-
$
03: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$2,652
Cost:
$9,152
$1,448 27,045 $1,204 162 - - $1,448
27,045
kWh
$1,204
162
kW-months/year
-
-
$
04: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$6,678
Cost:
-
- - $6,678 900 - - -
-
kWh
$6,678
900
kW-months/year
-
-
$
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$3,960
Cost:
$5,000
$3,960 73,943 - - - - $3,960
73,943
kWh
-
-
kW-months/year
-
-
$
06: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL Savings:
$3,000
Cost:
$1,000
- - - - $3,000 - -
-
kWh
-
-
kW-months/year
$3,000
-
$
TOTAL RECOMMENDED Savings:
$18,124
Cost:
$15,702
$6,750 126,063 $8,374 1,128 $3,000 - $6,750
126,063
kWh
$8,374
1,128
kW-months/year
$3,000
-
$
TOTAL IMPLEMENTED Savings:
$3,000
Cost:
$1,000
- - - - $3,000 - -
-
kWh
-
-
kW-months/year
$3,000
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand By-product Production Electricity Usage Electricity Demand By-product Production