Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2003 |
Principal Product | Plastic grocery bags and plastic sheeting |
NAICS | 326111 - Plastics Bag and Pouch Manufacturing |
SIC | 3081 - Unsupported Plastics Film & Sheet |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 82,400 |
Annual Production | 2,147,483,647 Pieces |
Production Hrs. Annual | 8,600 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $867,779 | 32,086,500 | kWh | $0.03 |
Electricity Demand | $814,527 | 50,575 | kW-months/year | $16.11 |
Electricity Fees | $413 | - | $ | - |
TOTAL ENERGY COSTS | $1,682,719 | |||
RECOMMENDED SAVINGS* | $334,635 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $311,820 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.113 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT |
Savings: $272,200 Cost: $118,250 |
- | - | - | - | - | - | $(-5,000) | - | $277,200 | - |
- - kWh |
- - kW-months/year |
- - $ |
$(-5,000) - $ |
$277,200 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $16,965 Cost: $5,128 |
$8,353 | 308,224 | $8,612 | 538 | - | - | - | - | - | - |
$8,353 308,224 kWh |
$8,612 538 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $14,974 Cost: $9,174 |
$8,192 | 303,410 | $6,782 | 423 | - | - | - | - | - | - |
$8,192 303,410 kWh |
$6,782 423 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $4,027 Cost: $1,719 |
$2,208 | 81,490 | $1,819 | 114 | - | - | - | - | - | - |
$2,208 81,490 kWh |
$1,819 114 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $7,908 Cost: $800 |
$4,368 | 161,184 | $3,540 | 221 | - | - | - | - | - | - |
$4,368 161,184 kWh |
$3,540 221 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $3,654 Cost: $2,400 |
$(-18) | (-667) | $3,672 | 229 | - | - | - | - | - | - |
$(-18) (-667) kWh |
$3,672 229 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.711 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM |
Savings: $14,907 Cost: $640 |
$8,695 | 320,865 | $8,132 | 506 | $(-1,920) | - | - | - | - | - |
$8,695 320,865 kWh |
$8,132 506 kW-months/year |
$(-1,920) - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $334,635 Cost: $138,111 |
$31,798 | 1,174,506 | $32,557 | 2,031 | $(-1,920) | - | $(-5,000) | - | $277,200 | - | $31,798 1,174,506 kWh |
$32,557 2,031 kW-months/year |
$(-1,920) - $ |
$(-5,000) - $ |
$277,200 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $311,820 Cost: $136,671 |
$18,735 | 692,457 | $20,885 | 1,304 | - | - | $(-5,000) | - | $277,200 | - | $18,735 692,457 kWh |
$20,885 1,304 kW-months/year |
- - $ |
$(-5,000) - $ |
$277,200 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Increase in Production |