Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2003 |
Principal Product | School uniforms |
NAICS | 315210 - Cut and Sew Apparel Contractors |
SIC | 2369 - Girls', Children's, and Infants' Outerwear, Not Elsewhere Classified |
Sales | $10,000,000-$50,000,000 |
# of Employees | 140 |
Plant Area (Sq.Ft.) | 98,000 |
Annual Production | 500,000 Pieces |
Production Hrs. Annual | 2,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $29,068 | 572,200 | kWh | $0.05 |
Electricity Demand | $15,971 | 3,266 | kW-months/year | $4.89 |
Electricity Fees | $2,670 | - | $ | - |
LPG | $29,516 | 2,748 | MMBtu | $10.74 |
TOTAL ENERGY COSTS | $77,615 | |||
RECOMMENDED SAVINGS* | $4,121 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,770 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $728 Cost: $2,803 |
$462 | 9,093 | $266 | 54 | - | - | - | - | - | - |
$462 9,093 kWh |
$266 54 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,885 Cost: $610 |
$1,885 | 37,100 | - | - | - | - | - | - | - | - |
$1,885 37,100 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $990 Cost: $400 |
- | - | - | - | - | - | $390 | 26,000 | $600 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$390 26,000 lb |
$600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $167 Cost: $235 |
$132 | 2,606 | $35 | 7 | - | - | - | - | - | - |
$132 2,606 kWh |
$35 7 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2491 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING |
Savings: $351 Cost: $900 |
- | - | - | - | $351 | 29 | - | - | - | - |
- - kWh |
- - kW-months/year |
$351 29 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $4,121 Cost: $4,948 |
$2,479 | 48,799 | $301 | 61 | $351 | 29 | $390 | 26,000 | $600 | - | $2,479 48,799 kWh |
$301 61 kW-months/year |
$351 29 MMBtu |
$390 26,000 lb |
$600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,770 Cost: $4,048 |
$2,479 | 48,799 | $301 | 61 | - | - | $390 | 26,000 | $600 | - | $2,479 48,799 kWh |
$301 61 kW-months/year |
- - MMBtu |
$390 26,000 lb |
$600 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Solid Waste (non-haz) | Administrative Changes |