Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 2003
Principal Product Finished wood cabinet components
NAICS 337122 - Nonupholstered Wood Household Furniture Manufacturing
SIC 2499 - Wood Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 65
Plant Area (Sq.Ft.) 173,000
Annual Production 3,100,000 Pieces
Production Hrs. Annual 4,000
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $65,975 1,286,323 kWh $0.05
Electricity Demand $19,106 5,538 kW-months/year $3.45
Electricity Fees $196 - $ -
LPG $75,213 7,697 MMBtu $9.77
TOTAL ENERGY COSTS $160,490
RECOMMENDED SAVINGS* $2,069 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,176
#|Description Savings
Cost
Status Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG
$ kWh $ kW-months/year $ MMBtu
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$705
Cost:
$500
- - - - $705 72 -
-
kWh
-
-
kW-months/year
$705
72
MMBtu
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$232
Cost:
$83
$152 3,160 $80 19 - - $152
3,160
kWh
$80
19
kW-months/year
-
-
MMBtu
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$65
Cost:
-
- - $65 15 - - -
-
kWh
$65
15
kW-months/year
-
-
MMBtu
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$51
Cost:
$104
$51 1,065 - - - - $51
1,065
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.7134 USE PHOTOCELL CONTROLS Savings:
$137
Cost:
$200
$110 2,300 $27 6 - - $110
2,300
kWh
$27
6
kW-months/year
-
-
MMBtu
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$879
Cost:
$390
$574 11,960 $305 72 - - $574
11,960
kWh
$305
72
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$2,069
Cost:
$1,277
$887 18,485 $477 112 $705 72 $887
18,485
kWh
$477
112
kW-months/year
$705
72
MMBtu
TOTAL IMPLEMENTED Savings:
$1,176
Cost:
$473
$726 15,120 $450 106 - - $726
15,120
kWh
$450
106
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG