Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2005 |
Principal Product | Rough cut lumber |
NAICS | 423310 - Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers |
SIC | 2420 - |
Sales | $5,000,000-$10,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 11,000 Thousand Feet |
Production Hrs. Annual | 2,000 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $35,042 | 1,525,200 | kWh | $0.02 |
Electricity Demand | $99,521 | 12,063 | kW-months/year | $8.25 |
Electricity Fees | $295 | - | $ | - |
TOTAL ENERGY COSTS | $134,858 | |||
RECOMMENDED SAVINGS* | $64,040 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $51,838 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | By-product Production | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $39,375 Cost: $1,000 |
- | - | - | - | - | - | - | - | $39,375 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$39,375 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $11,668 Cost: $20,000 |
- | - | $11,668 | 1,414 | - | - | - | - | - | - |
- - kWh |
$11,668 1,414 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $10,275 Cost: $18,500 |
$2,860 | 99,260 | $7,415 | 596 | - | - | - | - | - | - |
$2,860 99,260 kWh |
$7,415 596 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $443 Cost: $585 |
$123 | 4,263 | $320 | 26 | - | - | - | - | - | - |
$123 4,263 kWh |
$320 26 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,927 Cost: $5,332 |
$394 | 13,677 | $1,533 | 123 | - | - | - | - | - | - |
$394 13,677 kWh |
$1,533 123 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $244 Cost: $100 |
$263 | 9,120 | $681 | 55 | $(-400) | - | $(-300) | - | - | - |
$263 9,120 kWh |
$681 55 kW-months/year |
$(-400) - $ |
$(-300) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $108 Cost: $250 |
$30 | 1,042 | $78 | 6 | - | - | - | - | - | - |
$30 1,042 kWh |
$78 6 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $64,040 Cost: $45,767 |
$3,670 | 127,362 | $21,695 | 2,220 | $(-400) | - | $(-300) | - | $39,375 | - | $3,670 127,362 kWh |
$21,695 2,220 kW-months/year |
$(-400) - $ |
$(-300) - $ |
$39,375 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $51,838 Cost: $21,935 |
$416 | 14,425 | $12,747 | 1,501 | $(-400) | - | $(-300) | - | $39,375 | - | $416 14,425 kWh |
$12,747 1,501 kW-months/year |
$(-400) - $ |
$(-300) - $ |
$39,375 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||