Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2008 |
Principal Product | Cutting tools |
NAICS | 333515 - Cutting Tool and Machine Tool Accessory Manufacturing |
SIC | 3545 - Machine Tool Accessories |
Sales | $10,000,000-$50,000,000 |
# of Employees | 170 |
Plant Area (Sq.Ft.) | 109,000 |
Annual Production | 2,600,000 Pieces |
Production Hrs. Annual | 7,200 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $400,563 | 8,958,750 | kWh | $0.04 |
Electricity Demand | $154,483 | 18,422 | kW-months/year | $8.39 |
Electricity Fees | $17,666 | - | $ | - |
Natural Gas | $11,684 | 918 | MMBtu | $12.73 |
TOTAL ENERGY COSTS | $584,396 | |||
RECOMMENDED SAVINGS* | $28,736 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,061 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $3,790 Cost: $7,000 |
$3,790 | 94,848 | - | - | - | - | - | - |
$3,790 94,848 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.3128 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS |
Savings: $15,885 Cost: $41,750 |
$5,638 | 125,559 | $1,747 | 209 | $(-5,000) | - | $13,500 | - |
$5,638 125,559 kWh |
$1,747 209 kW-months/year |
$(-5,000) - $ |
$13,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $3,903 Cost: $7,500 |
$3,903 | 86,916 | - | - | - | - | - | - |
$3,903 86,916 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,473 Cost: $1,680 |
$1,125 | 25,056 | $348 | 42 | - | - | - | - |
$1,125 25,056 kWh |
$348 42 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,999 Cost: $4,820 |
$1,526 | 33,984 | $473 | 57 | - | - | - | - |
$1,526 33,984 kWh |
$473 57 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $1,686 Cost: $2,173 |
$1,288 | 28,679 | $398 | 48 | - | - | - | - |
$1,288 28,679 kWh |
$398 48 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $28,736 Cost: $64,923 |
$17,270 | 395,042 | $2,966 | 356 | $(-5,000) | - | $13,500 | - | $17,270 395,042 kWh |
$2,966 356 kW-months/year |
$(-5,000) - $ |
$13,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,061 Cost: $16,173 |
$7,842 | 174,635 | $1,219 | 147 | - | - | - | - | $7,842 174,635 kWh |
$1,219 147 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |