Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2011 |
Principal Product | Gas dispensers |
NAICS | 333913 - Measuring and Dispensing Pump Manufacturing |
SIC | 3586 - Measuring And Dispensing Pumps |
Sales | $100,000,000-$500,000,000 |
# of Employees | 1,100 |
Plant Area (Sq.Ft.) | 885,000 |
Annual Production | 25,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $850,650 | 17,352,000 | kWh | $0.05 |
Electricity Demand | $183,072 | 40,206 | kW-months/year | $4.55 |
Electricity Fees | $36 | - | $ | - |
Natural Gas | $319,758 | 55,184 | MMBtu | $5.79 |
TOTAL ENERGY COSTS | $1,353,516 | |||
RECOMMENDED SAVINGS* | $97,949 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $3,623 Cost: $1,000 |
- | - | - | - | $3,623 | 623 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,623 623 MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1224 REPLACE BOILER |
Savings: $17,336 Cost: $37,000 |
- | - | - | - | $17,336 | 2,979 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$17,336 2,979 MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $15,021 Cost: $10,000 |
- | - | - | - | $8,429 | 1,488 | - | - | - | - | $6,592 | - |
- - kWh |
- - kW-months/year |
$8,429 1,488 MMBtu |
- - $ |
- - $ |
$6,592 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $3,316 Cost: $1,618 |
- | - | - | - | $3,316 | 569 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,316 569 MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $8,982 Cost: $38,000 |
- | - | - | - | $8,982 | 1,543 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,982 1,543 MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2514 COVER OPEN TANKS |
Savings: $11,237 Cost: $15,000 |
$8,966 | 244,360 | $2,271 | 335 | - | - | - | - | - | - | - | - |
$8,966 244,360 kWh |
$2,271 335 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $15,795 Cost: $1,500 |
$15,795 | 506,225 | - | - | - | - | - | - | - | - | - | - |
$15,795 506,225 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $10,815 Cost: $22,930 |
- | - | - | - | $10,815 | 1,859 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,815 1,859 MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,211 Cost: $100 |
$4,745 | 129,322 | $1,466 | 178 | - | - | - | - | - | - | - | - |
$4,745 129,322 kWh |
$1,466 178 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,027 Cost: $100 |
$2,374 | 64,696 | $733 | 89 | - | - | $(-600) | - | $(-480) | - | - | - |
$2,374 64,696 kWh |
$733 89 kW-months/year |
- - MMBtu |
$(-600) - $ |
$(-480) - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $3,586 Cost: - |
$3,586 | - | - | - | - | - | - | - | - | - | - | - |
$3,586 - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $97,949 Cost: $127,248 |
$35,466 | 944,603 | $4,470 | 602 | $52,501 | 9,061 | $(-600) | - | $(-480) | - | $6,592 | - | $35,466 944,603 kWh |
$4,470 602 kW-months/year |
$52,501 9,061 MMBtu |
$(-600) - $ |
$(-480) - $ |
$6,592 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption |