Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2011 |
Principal Product | Electrical wiring devices |
NAICS | 335931 - Current-Carrying Wiring Device Manufacturing |
SIC | 3643 - Current-carrying Wiring Devices |
Sales | $50,000,000-$100,000,000 |
# of Employees | 319 |
Plant Area (Sq.Ft.) | 240,000 |
Annual Production | 147,000,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,079,930 | 24,218,579 | kWh | $0.04 |
Electricity Demand | $488,509 | 52,462 | kW-months/year | $9.31 |
Electricity Fees | $3,189 | - | $ | - |
Natural Gas | $56,695 | 7,393 | MMBtu | $7.67 |
TOTAL ENERGY COSTS | $1,628,323 | |||
RECOMMENDED SAVINGS* | $61,739 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,590 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $9,839 Cost: - |
$8,993 | 164,640 | $846 | 235 | - | - | - | - | - | - | - | - |
$8,993 164,640 kWh |
$846 235 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,052 Cost: $100 |
$5,119 | 93,720 | $613 | 170 | - | - | $(-1,200) | - | $(-480) | - | - | - |
$5,119 93,720 kWh |
$613 170 kW-months/year |
- - MMBtu |
$(-1,200) - $ |
$(-480) - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,314 Cost: $150 |
$1,161 | 21,250 | $153 | 42 | - | - | - | - | - | - | - | - |
$1,161 21,250 kWh |
$153 42 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $11,250 Cost: $22,950 |
$11,395 | 208,620 | $1,502 | 417 | - | - | - | - | - | - | $(-1,647) | - |
$11,395 208,620 kWh |
$1,502 417 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$(-1,647) - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1224 REPLACE BOILER |
Savings: $3,539 Cost: $11,800 |
- | - | - | - | $3,539 | 438 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,539 438 MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,385 Cost: $4,833 |
$1,076 | 19,695 | $309 | 86 | - | - | - | - | - | - | - | - |
$1,076 19,695 kWh |
$309 86 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $30,360 Cost: $161,900 |
$35,791 | 655,268 | - | - | - | - | - | - | - | - | $(-5,431) | - |
$35,791 655,268 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$(-5,431) - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $61,739 Cost: $201,733 |
$63,535 | 1,163,193 | $3,423 | 950 | $3,539 | 438 | $(-1,200) | - | $(-480) | - | $(-7,078) | - | $63,535 1,163,193 kWh |
$3,423 950 kW-months/year |
$3,539 438 MMBtu |
$(-1,200) - $ |
$(-480) - $ |
$(-7,078) - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,590 Cost: $5,083 |
$16,349 | 299,305 | $1,921 | 533 | - | - | $(-1,200) | - | $(-480) | - | - | - | $16,349 299,305 kWh |
$1,921 533 kW-months/year |
- - MMBtu |
$(-1,200) - $ |
$(-480) - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption |