Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2013 |
Principal Product | Steel drums |
NAICS | 332439 - Other Metal Container Manufacturing |
SIC | 3499 - Fabricated Metal Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 62 |
Plant Area (Sq.Ft.) | 74,000 |
Annual Production | 1,300,000 Pieces |
Production Hrs. Annual | 2,375 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $111,289 | 2,219,654 | kWh | $0.05 |
Electricity Demand | $46,720 | 8,347 | kW-months/year | $5.60 |
Electricity Fees | $2,321 | - | $ | - |
Natural Gas | $254,464 | 42,137 | MMBtu | $6.04 |
TOTAL ENERGY COSTS | $414,794 | |||
RECOMMENDED SAVINGS* | $26,483 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,824 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2425 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER |
Savings: $13,288 Cost: $25,000 |
- | - | - | - | $13,288 | 2,200 | - | - | - | - |
- - kWh |
- - kW-months/year |
$13,288 2,200 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $5,220 Cost: $31,024 |
$(-20,347) | (-406,125) | $(-7,858) | (-1,404) | $33,425 | 5,534 | - | - | - | - |
$(-20,347) (-406,125) kWh |
$(-7,858) (-1,404) kW-months/year |
$33,425 5,534 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,560 Cost: $4,950 |
- | - | - | - | $2,560 | 424 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,560 424 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $2,591 Cost: $10,980 |
$2,241 | 44,735 | $350 | 63 | - | - | - | - | - | - |
$2,241 44,735 kWh |
$350 63 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,248 Cost: $11,314 |
$1,021 | 20,378 | $576 | 103 | - | - | - | - | $651 | - |
$1,021 20,378 kWh |
$576 103 kW-months/year |
- - MMBtu |
- - $ |
$651 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $576 Cost: $100 |
$714 | 14,250 | $402 | 72 | - | - | $(-300) | - | $(-240) | - |
$714 14,250 kWh |
$402 72 kW-months/year |
- - MMBtu |
$(-300) - $ |
$(-240) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $26,483 Cost: $83,368 |
$(-16,371) | (-326,762) | $(-6,530) | (-1,166) | $49,273 | 8,158 | $(-300) | - | $411 | - | $(-16,371) (-326,762) kWh |
$(-6,530) (-1,166) kW-months/year |
$49,273 8,158 MMBtu |
$(-300) - $ |
$411 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,824 Cost: $11,414 |
$1,735 | 34,628 | $978 | 175 | - | - | $(-300) | - | $411 | - | $1,735 34,628 kWh |
$978 175 kW-months/year |
- - MMBtu |
$(-300) - $ |
$411 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |