Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2014 |
Principal Product | High voltage cable |
NAICS | 335929 - Other Communication and Energy Wire Manufacturing |
SIC | 3357 - Nonferrous Wiredrawing & Insulating |
Sales | $50,000,000-$100,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 303,281 |
Annual Production | 1,970 Thousand Feet |
Production Hrs. Annual | 8,400 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $350,803 | 10,726,394 | kWh | $0.03 |
Electricity Demand | $130,036 | 20,074 | kW-months/year | $6.48 |
Electricity Fees | $(-70,781) | - | $ | - |
Natural Gas | $57,583 | 6,356 | MMBtu | $9.06 |
TOTAL ENERGY COSTS | $467,641 | |||
RECOMMENDED SAVINGS* | $40,582 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $26,905 Cost: $50,000 |
$(-7,663) | (-234,346) | $(-3,032) | (-469) | - | - | $(-2,400) | - | $40,000 | - |
$(-7,663) (-234,346) kWh |
$(-3,032) (-469) kW-months/year |
- - MMBtu |
$(-2,400) - $ |
$40,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,351 Cost: $1,591 |
$3,351 | 102,464 | - | - | - | - | - | - | - | - |
$3,351 102,464 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $1,741 Cost: $7,000 |
$1,741 | 53,246 | - | - | - | - | - | - | - | - |
$1,741 53,246 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $66 Cost: $25 |
$30 | 924 | $17 | 3 | - | - | - | - | $19 | - |
$30 924 kWh |
$17 3 kW-months/year |
- - MMBtu |
- - $ |
$19 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $165 Cost: $160 |
$165 | 5,040 | - | - | - | - | - | - | - | - |
$165 5,040 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $390 Cost: $990 |
$64 | 1,944 | $67 | 11 | - | - | - | - | $259 | - |
$64 1,944 kWh |
$67 11 kW-months/year |
- - MMBtu |
- - $ |
$259 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,104 Cost: $12,169 |
$1,705 | 52,135 | $710 | 110 | - | - | - | - | $689 | - |
$1,705 52,135 kWh |
$710 110 kW-months/year |
- - MMBtu |
- - $ |
$689 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $2,554 Cost: $5,000 |
$1,830 | 55,950 | $724 | 112 | - | - | - | - | - | - |
$1,830 55,950 kWh |
$724 112 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,306 Cost: $5,000 |
- | - | - | - | $2,306 | 255 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,306 255 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $40,582 Cost: $81,935 |
$1,223 | 37,357 | $(-1,514) | (-233) | $2,306 | 255 | $(-2,400) | - | $40,967 | - | $1,223 37,357 kWh |
$(-1,514) (-233) kW-months/year |
$2,306 255 MMBtu |
$(-2,400) - $ |
$40,967 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Ancillary Material Cost |