Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2017 |
Principal Product | Hydraulic pumps and motors |
NAICS | 333911 - Pump and Pumping Equipment Manufacturing |
SIC | 3561 - Pumps And Pumping Equipment |
Sales | $50,000,000-$100,000,000 |
# of Employees | 259 |
Plant Area (Sq.Ft.) | 184,000 |
Annual Production | 180,000 Pieces |
Production Hrs. Annual | 6,864 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $665,035 | 10,845,400 | kWh | $0.06 |
Electricity Demand | $192,469 | 23,715 | kW-months/year | $8.12 |
Natural Gas | $15,852 | 2,229 | MMBtu | $7.11 |
TOTAL ENERGY COSTS | $873,356 | |||
RECOMMENDED SAVINGS* | $135,158 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $72,078 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $64,592 Cost: $221,073 |
$47,219 | 770,296 | $11,234 | 1,383 | - | - | $6,139 | - | - | - |
$47,219 770,296 kWh |
$11,234 1,383 kW-months/year |
- - $ |
$6,139 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $375 Cost: $75 |
$252 | 4,118 | $58 | 7 | - | - | $65 | - | - | - |
$252 4,118 kWh |
$58 7 kW-months/year |
- - $ |
$65 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $798 Cost: $400 |
$798 | 13,024 | - | - | - | - | - | - | - | - |
$798 13,024 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $62,705 Cost: $158,000 |
$42,413 | 691,892 | $26,225 | 3,230 | - | - | - | - | $(-5,933) | - |
$42,413 691,892 kWh |
$26,225 3,230 kW-months/year |
- - $ |
- - $ |
$(-5,933) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,666 Cost: $500 |
$3,139 | 51,205 | $727 | 90 | $(-100) | - | $(-100) | - | - | - |
$3,139 51,205 kWh |
$727 90 kW-months/year |
$(-100) - $ |
$(-100) - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,022 Cost: $1,200 |
$3,022 | 49,280 | - | - | - | - | - | - | - | - |
$3,022 49,280 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $135,158 Cost: $381,248 |
$96,843 | 1,579,815 | $38,244 | 4,710 | $(-100) | - | $6,104 | - | $(-5,933) | - | $96,843 1,579,815 kWh |
$38,244 4,710 kW-months/year |
$(-100) - $ |
$6,104 - $ |
$(-5,933) - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $72,078 Cost: $223,173 |
$54,178 | 883,805 | $11,961 | 1,473 | $(-100) | - | $6,039 | - | - | - | $54,178 883,805 kWh |
$11,961 1,473 kW-months/year |
$(-100) - $ |
$6,039 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Water Consumption |