Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2017 |
Principal Product | Wastewater treatment plant |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $50,000,000-$100,000,000 |
# of Employees | 37 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 10,000,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $351,292 | 13,972,000 | kWh | $0.03 |
Electricity Demand | $516,032 | 29,698 | kW-months/year | $17.38 |
Electricity Fees | $98,484 | - | $ | - |
Natural Gas | $40,000 | 10,075 | MMBtu | $3.97 |
TOTAL ENERGY COSTS | $1,005,808 | |||
RECOMMENDED SAVINGS* | $82,498 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,052 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $24,750 Cost: $80,000 |
- | - | - | - | $24,750 | 6,234 | - | - |
- - kWh |
- - kW-months/year |
$24,750 6,234 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $4,845 Cost: $38,000 |
$2,343 | 103,200 | $2,502 | 144 | - | - | - | - |
$2,343 103,200 kWh |
$2,502 144 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3412 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR |
Savings: $26,851 Cost: $133,000 |
$12,982 | 571,900 | $13,869 | 798 | - | - | - | - |
$12,982 571,900 kWh |
$13,869 798 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $23,766 Cost: $97,500 |
$6,711 | 295,650 | $14,075 | 840 | - | - | $2,980 | - |
$6,711 295,650 kWh |
$14,075 840 kW-months/year |
- - MMBtu |
$2,980 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,286 Cost: $5,865 |
$891 | 39,257 | $1,395 | 78 | - | - | - | - |
$891 39,257 kWh |
$1,395 78 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $82,498 Cost: $354,365 |
$22,927 | 1,010,007 | $31,841 | 1,860 | $24,750 | 6,234 | $2,980 | - | $22,927 1,010,007 kWh |
$31,841 1,860 kW-months/year |
$24,750 6,234 MMBtu |
$2,980 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,052 Cost: $103,365 |
$7,602 | 334,907 | $15,470 | 918 | - | - | $2,980 | - | $7,602 334,907 kWh |
$15,470 918 kW-months/year |
- - MMBtu |
$2,980 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost |