Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2017 |
Principal Product | Boat engine testing |
NAICS | 333618 - Other Engine Equipment Manufacturing |
SIC | 3519 - Internal Combustion Engines, Nec |
Sales | <$500,000 |
# of Employees | 230 |
Plant Area (Sq.Ft.) | 117,000 |
Annual Production | 1 Pieces |
Production Hrs. Annual | 3,625 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $91,398 | 1,527,171 | kWh | $0.06 |
Electricity Demand | $28,437 | 4,436 | kW-months/year | $6.41 |
Electricity Fees | $1,186 | - | $ | - |
Natural Gas | $11,701 | 1,590 | MMBtu | $7.36 |
TOTAL ENERGY COSTS | $132,722 | |||
RECOMMENDED SAVINGS* | $66,427 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,200 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Usage | Water Disposal | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Usage | Water Disposal | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $37,015 Cost: $250 |
$30,834 | 1 | $6,917 | 1 | $(-736) | - | - | - | - | - | - | - | - | - |
$30,834 1 kWh |
$6,917 1 kW-months/year |
$(-736) - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $3,356 Cost: - |
- | - | - | - | - | - | $3,356 | 368 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$3,356 368 MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $3,139 Cost: $4,200 |
- | - | - | - | - | - | - | - | - | - | $3,259 | 508 | $(-120) | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$3,259 508 Tgal |
$(-120) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $15,073 Cost: $6,000 |
$496 | 8,560 | $1,207 | 173 | - | - | $11,698 | 1,284 | $1,672 | 126,975 | - | - | - | - |
$496 8,560 kWh |
$1,207 173 kW-months/year |
- - $ |
$11,698 1,284 MMBtu |
$1,672 126,975 Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,529 Cost: $9,666 |
$2,225 | 26,613 | $1,072 | 122 | - | - | - | - | - | - | - | - | $232 | - |
$2,225 26,613 kWh |
$1,072 122 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
$232 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,501 Cost: $6,171 |
$767 | 13,239 | $423 | 61 | - | - | - | - | - | - | - | - | $311 | - |
$767 13,239 kWh |
$423 61 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
$311 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $45 Cost: $100 |
$29 | 488 | $16 | 2 | - | - | - | - | - | - | - | - | - | - |
$29 488 kWh |
$16 2 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6213 TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS |
Savings: $48 Cost: $65 |
$40 | 684 | $8 | 1 | - | - | - | - | - | - | - | - | - | - |
$40 684 kWh |
$8 1 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,273 Cost: $230 |
$832 | 9,957 | $441 | 50 | - | - | - | - | - | - | - | - | - | - |
$832 9,957 kWh |
$441 50 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $1,448 Cost: $5,865 |
$900 | 15,539 | $548 | 78 | - | - | - | - | - | - | - | - | - | - |
$900 15,539 kWh |
$548 78 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $66,427 Cost: $32,547 |
$36,123 | 75,081 | $10,632 | 488 | $(-736) | - | $15,054 | 1,652 | $1,672 | 126,975 | $3,259 | 508 | $423 | - | $36,123 75,081 kWh |
$10,632 488 kW-months/year |
$(-736) - $ |
$15,054 1,652 MMBtu |
$1,672 126,975 Tgal |
$3,259 508 Tgal |
$423 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,200 Cost: $22,097 |
$4,793 | 66,520 | $2,508 | 314 | - | - | $3,356 | 368 | - | - | - | - | $543 | - | $4,793 66,520 kWh |
$2,508 314 kW-months/year |
- - $ |
$3,356 368 MMBtu |
- - Tgal |
- - Tgal |
$543 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Usage | Water Disposal | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Usage | Water Disposal | Ancillary Material Cost |